English
Language : 

PE85N1009 Datasheet, PDF (2/5 Pages) Pasternack Enterprises, Inc. – 1.85mm Precision Calibrated Noise Source Module, Output ENR of 7 dB, +28 VDC, 100 MHz to 60 GHz, Calibration Standard
1.85mm Precision Calibrated Noise Source Module, Output ENR
of 7 dB, +28 VDC, 100 MHz to 60 GHz, Calibration Standard
Noise Generators Technical Data Sheet
PE85N1009
Performance by Frequency
Description
F1
F2
F3
F4
F5
Units
Frequency Range
0.1 to 5
5 to 18
18 to 26
26 to 40
GHz
VSWR, Typ
1.15:1
1.25:1
1.35:1
1.5:1
.
Mechanical Specifications
Size
Length
Width/Dia.
Height
.
Weight
.
Package Type
Connectors
DC Connector
Output Connector
Environmental Specifications
Temperature
Operating Range
Storage Range
Environment
Humidity
Shock
Vibration
Altitude
Temperature Cycle
Thermal Shock
ESD Sensitivity
1.25 in [31.75 mm]
0.75 in [19.05 mm]
0.5 in [12.7 mm]
0.32 lbs [145.15 g]
Connectorized Module
BNC Female
1.85mm Male
-55 to +85 deg C
-65 to +125 deg C
MIL-STD-202F, Method 103, Cond B (96 hrs@95%
R.H.)
MIL-STD-202F, Method 213, Cond B (100g, 6 msec)
MIL-STD-202F,Method 204,Cond B(0.6” 2x ampl or15g)
MIL-STD-202F, Method 105, Condition B (50,000 ft)
MIL-STD-202F, Method 105C, Condition D (5 cycles)
MIL-STD-202F, Method 107, Conditon A (5 cycles)
ESD Sensitive Material, Transport material in Approved
ESD bags. Handle only in ESD Workstation.
Compliance Certifications (visit www.Pasternack.com for current document)
Not RoHS Compliant
REACH Compliant
12/17/2015
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: 1.85mm Precision Calibrated Noise Source Module, Output ENR of 7 dB, +28 VDC, 100 MHz
to 60 GHz, Calibration Standard PE85N1009
PE85N1009 REV 1.0
2