English
Language : 

PE85N1009 Datasheet, PDF (1/5 Pages) Pasternack Enterprises, Inc. – 1.85mm Precision Calibrated Noise Source Module, Output ENR of 7 dB, +28 VDC, 100 MHz to 60 GHz, Calibration Standard
1.85mm Precision Calibrated Noise Source Module, Output ENR
of 7 dB, +28 VDC, 100 MHz to 60 GHz, Calibration Standard
Noise Generators Technical Data Sheet
PE85N1009
Features
• 10 MHz to 6 GHz Bandwidth
• Excellent Stability
• Noise Output Temperature Variation: <0.01 dB/°C
• Noise Output Variation <0.1 dB/%V
• Rugged Package Design supports output Female SMA
connector
• Designed to meet MIL-STD-202F environmental test
conditions
• Calibrated Precision Noise Source
• VSWR < 1.35:1
• Outupt Noise ENR 14 dB typical
• Highly Stable and Accurate Performance
• Maximum Reverse Power 1 Watt
Applications
• Noise Figure Measurements
• Built-In Test equipment for signal
strenth calibrators and radar
applications
• Automatic Test Equipment (ATE)
.
• Jamming
• Baseband Signal Simulation
• Additive White Gausian Noise
(AWGN) source for Error Rate
Measurements
• Increase dynamic range of A/D
Converters
• SATCOM for bit error rate (BER)
and noise figure
• Can be used as a Jitter source.
Description
The PE85N1009 is a coaxial packaged calibrated precision Noise Source module which operates over a ultra wide frequency
range from 0.1 GHz to 60 GHz. es very low VSWR < 1.5:1 typical that significantly increases mesurement accuracy and
is ideal for Noise Figure measurements and built-in applications. This model operates at +28 Vdc and features an output
ENR level ranging from 7 to 21 dB with 10 MHz calibration points every GHz. Highly stable and accurate performance is
specified over -55°C to +85°C with Noise Output Temperature Variation <0.009 dB/°C and Noise Output Variation < 0.002
dB/%V. Maximum Reverse Power is 1 Watt. The rugged industry standard profile package design supports an input Female
BNC connector for DC bias and an output Male 1.85mm (V) connector. Additionally, the model is designed to meet a variety
of demanding MIL-STD-202F environmental test conditions including Humidity, Thermal Shock, and Vibration for added
confidence for highly reliable operation.
Electrical Specifications
RF Characteristics
Description
Minimum
Typical
Maximum
Units
Frequency Range
0.1
60
GHz
Impedance 50 Ohms
Output ENR
7
21
dB
Output Variation vs Input Voltage
0.002
dB/%V
Output Variation vs Temperature
0.009
dB/deg C
Bias Voltage 1
28 ±2
Volts
Input Current 1
30
mA
Reverse Power
1
Watts
Calibration Points
.
Every GHz
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: 1.85mm Precision Calibrated Noise Source Module, Output ENR of 7 dB, +28 VDC, 100 MHz
to 60 GHz, Calibration Standard PE85N1009
PE85N1009 REV 1.0
1