English
Language : 

HE-PV Datasheet, PDF (3/4 Pages) Panasonic Battery Group – HE RELAYS PV Type
HE PV Type
REFERENCE DATA
1.-(1) Coil temperature rise
(Standard type)
Sample: HE1aN-P-DC9V-H18, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C 77°F, 60°C 140°F, 85°C
185°F
Contact carrying current: 35A
70
60
25°C
50
60°C
40
85°C
30
20
10
0 50
60 70 80 90 100
Coil applied voltage, %V
1.-(2) Coil temperature rise
(High capacity type)
Sample: HE1aN-P-DC9V-Y5, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C 77°F, 60°C 140°F, 85°C
185°F
Contact carrying current: 48A
70
60
25°C
50
60°C
40
85°C
30
20
10
0 50
60 70 80 90 100
Coil applied voltage, %V
2.-(1) Electrical life test (Standard type, Resistive load 250V AC, 35A at 85°C 185°F)
Sample: HE1aN-P-DC9V-H18, 6 pcs.
Change of pick-up and drop-out voltage
Operation frequency: 6 times/min.
(ON/OFF = 1.0s : 9.0s)
9
8
Circuit:
7
250V AC
9V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
6
5
Pick-up voltage
Max.
x
4
Min.
3
2
Drop-out voltage
Max.
x
Min.
1
00
3
No. of operations, ×104
2.-(2) Electrical life test (High capacity type, Resistive load 250V AC, 48A at 85°C 185°F)
Sample: HE1aN-P-DC9V-Y5, 6 pcs.
Operation frequency: 6 times/min.
Change of pick-up and drop-out voltage
(ON/OFF = 1.0s : 9.0s)
9
8
Circuit:
7
250V AC
9V DC
Contact
welding
detection
and Mis-
contacting
detection
circuit
6
5
Pick-up voltage
Max.
x
4
Min.
3
2
Drop-out voltage
Max.
x
Min.
1
00
3
No. of operations, ×104
Change of contact resistance
100
90
80
70
60
50
40
30
20
10
00
No. of operations, ×104
Max.
x
Min.
3
Change of contact resistance
100
90
80
70
60
50
40
30
20
10
00
No. of operations, ×104
Max.
x
Min.
3
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
ASCTB101E 201208-T