English
Language : 

HE-PV Datasheet, PDF (2/4 Pages) Panasonic Battery Group – HE RELAYS PV Type
HE PV Type
TYPES
Nominal coil
voltage
Standard type*
Part No.
6V DC
HE1aN-P-DC6V-H18
9V DC
HE1aN-P-DC9V-H18
12V DC
HE1aN-P-DC12V-H18
24V DC
HE1aN-P-DC24V-H18
Standard packing: Carton: 20 pcs.; Case: 100 pcs.
*Standard 6V, 12V and 24V DC type: Certified by UL/C-UL (Standard 9V type: Certified by UL/C-UL and VDE)
High capacity type
Part No.
HE1aN-P-DC6V-Y5
HE1aN-P-DC9V-Y5
HE1aN-P-DC12V-Y5
HE1aN-P-DC24V-Y5
RATING
1. Coil data
Nominal coil
voltage
6V DC
9V DC
12V DC
24V DC
Pick-up voltage
(at 20°C 68°F)
(Initial)
70%V or less of
nominal voltage
Drop-out voltage
(at 20°C 68°F)
(Initial)
10%V or more of
nominal voltage
Nominal operating
current
[±10%] (at 20°C 68°F)
320mA
213mA
160mA
80mA
Coil resistance
[±10%] (at 20°C 68°F)
18.8Ω
42.2Ω
75.0Ω
300.0Ω
Nominal operating
power
1,920mW
Max. applied voltage
(at 20°C 68°F)
110%V of
nominal voltage
2. Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity
Contact carring power
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Breakdown
Between open contacts
voltage (Initial) Between contact and coil
Surge breakdown voltage*2
(Between contact and coil) (Initial)
Temperature rise
Coil hold voltage*3
Operate time (at 20°C 68°F)
Release time (at 20°C 68°F)*5
Shock
resistance
Functional
Destructive
Vibration
resistance
Functional
Destructive
Mechanical
Resistive load
Electrical
Inductive load
Conditions for operation, transport and
storage*4
Max. operating speed
Specifications
Standard type
High capacity type
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type
AgNi type
35 A 250 V AC (Resistive load)
48 A 250 V AC (Resistive load)
8,750 VA (Resistive load)
12,000 VA (Resistive load)
250 V AC
35 A (AC)
48 A (AC)
1,920 mW
100 mA 5 V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
2,000 Vrms for 1 min. (Detection current: 10 mA)
5,000 Vrms for 1 min. (Detection current: 10 mA)
10,000 V
Max. 60°C 140°F (By resistive method,
Max. 60°C 140°F (By resistive method,
contact carrying current: 35A, 100%V of nominal contact carrying current: 48A, 100%V of nominal
coil voltage at 55°C 131°F.)
coil voltage at 55°C 131°F.)
Max. 30°C 86°F (By resistive method, contact
carrying current: 35A, 60%V of nominal coil
voltage at 85°C 185°F.)
Max. 30°C 86°F (By resistive method, contact
carrying current: 48A, 60%V of nominal coil
voltage at 85°C 185°F.)
40 to 100%V (Contact carrying current:
35A, at 20°C 68°F),
50 to 100%V (Contact carrying current:
35A, at 55°C 131°F),
50 to 60%V (Contact carrying current:
35A, at 85°C 185°F)
40 to 100%V (Contact carrying current:
48A, at 20°C 68°F),
50 to 100%V (Contact carrying current:
48A, at 55°C 131°F),
50 to 60%V (Contact carrying current:
48A, at 85°C 185°F)
Max. 30 ms (nominal coil voltage, excluding contact bounce time)
Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode)
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Min. 106 (at 180 times/min.)
Min. 3×104 (35 A 250 V AC) (ON : OFF = 1s : 9s) Min. 3×104 (48 A 250 V AC) (ON : OFF = 1s : 9s)
Endurance: 48 A 250 V AC (cosφ = 0.8),
—
Min. 3×104 (ON : OFF = 0.1s : 10s)
Overload: 72 A 250 V AC (cosφ = 0.8),
Min. 50 (ON : OFF = 0.1s : 10s)
Ambient temperature:
–50 to +55°C –58 to +131°F (When nominal coil voltage applied)
–50 to +85°C –58 to +185°F (When applied coil hold voltage is 50% to 60% of nominal coil voltage)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);
Atmospheric pressure: 86 to 106 kPa
6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s)
Approx. 80 g 2.82 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*3. Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage.
*4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*5. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.
ASCTB101E 201208-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/