RATING
1. Coil data
Contact
Nominal coil
arrangement
voltage
1 Form C
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Pick-up voltage
(at 20°C 68°F)
75%V or less of
nominal voltage
(Initial)
75%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
100mA
50mA
33.3mA
30mA
25mA
16.7mA
12.5mA
6.25mA
133.3mA
66.7mA
44.5mA
40mA
33.3mA
22.2mA
16.7mA
8.3mA
Coil resistance
[±10%] (at 20°C 68°F)
15Ω
60Ω
135Ω
166Ω
240Ω
540Ω
960Ω
3,840Ω
11.25Ω
45Ω
101.2Ω
125Ω
180Ω
405Ω
720Ω
2,880Ω
Nominal operating
power
150mW
200mW
Max. applied
voltage
(at 70°C 158°F)
140%V of
nominal voltage
120%V of
nominal voltage
2. Specifications
Characteristics
Item
Specifications
Contact
Arrangement
Initial contact resistance, max.
Contact material
1 Form C
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Ag+Au clad
Nominal switching capacity
1 A 30 V DC (resistive load)
Max. switching power
30 W (DC) (resistive load)
Max. switching voltage
60 V DC
Rating
Max. carrying current
2A
Max. switching current
1 A (30 V DC)
Min. switching capacity (Reference value)*1
1mA 1 V DC
Nominal operating power
Insulation resistance (Initial)
150/200mW
Min. 100MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Electrical
characteristics
Breakdown voltage Between open contacts
(Initial)
Between contact and coil
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil, nominal switching capacity.)
Max. 5 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Mechanical
characteristics
Release time [Reset time] (at 20°C 68°F)
Shock resistance
Vibration resistance
Functional
Destructive
Functional
Destructive
Max. 4 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
Expected life
Conditions
Mechanical
Electrical
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Min. 107 (at 180 cpm)
Min. 105 (1 A 30 V DC resistive) (at 20 cpm)
Ambient temperature: –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Unit weight
Approx. 1.8 g .063 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
ASCTB212E 201201-T