HY Datasheet, PDF (2/4 Pages) Panasonic Battery Group – Non-polarized 1 Form C relay that realizes nominal operating power of 150 mW | |||
|
◁ |
HY
RATING
1. Coil data
Contact
Nominal coil
arrangement
voltage
1 Form C
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
1.5V DC
3V DC
4.5V DC
5V DC
6V DC
9V DC
12V DC
24V DC
Pick-up voltage
(at 20°C 68°F)
75%V or less of
nominal voltage
(Initial)
75%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
Nominal operating
current
[±10%] (at 20°C 68°F)
100mA
50mA
33.3mA
30mA
25mA
16.7mA
12.5mA
6.25mA
133.3mA
66.7mA
44.5mA
40mA
33.3mA
22.2mA
16.7mA
8.3mA
Coil resistance
[±10%] (at 20°C 68°F)
15â¦
60â¦
135â¦
166â¦
240â¦
540â¦
960â¦
3,840â¦
11.25â¦
45â¦
101.2â¦
125â¦
180â¦
405â¦
720â¦
2,880â¦
Nominal operating
power
150mW
200mW
Max. applied
voltage
(at 70°C 158°F)
140%V of
nominal voltage
120%V of
nominal voltage
2. Speciï¬cations
Characteristics
Item
Speciï¬cations
Contact
Arrangement
Initial contact resistance, max.
Contact material
1 Form C
Max. 100 m⦠(By voltage drop 6 V DC 1A)
Ag+Au clad
Nominal switching capacity
1 A 30 V DC (resistive load)
Max. switching power
30 W (DC) (resistive load)
Max. switching voltage
60 V DC
Rating
Max. carrying current
2A
Max. switching current
1 A (30 V DC)
Min. switching capacity (Reference value)*1
1mA 1 V DC
Nominal operating power
Insulation resistance (Initial)
150/200mW
Min. 100M⦠(at 500V DC)
Measurement at same location as âInitial breakdown voltageâ section.
Electrical
characteristics
Breakdown voltage Between open contacts
(Initial)
Between contact and coil
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil, nominal switching capacity.)
Max. 5 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Mechanical
characteristics
Release time [Reset time] (at 20°C 68°F)
Shock resistance
Vibration resistance
Functional
Destructive
Functional
Destructive
Max. 4 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
Expected life
Conditions
Mechanical
Electrical
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Min. 107 (at 180 cpm)
Min. 105 (1 A 30 V DC resistive) (at 20 cpm)
Ambient temperature: â40°C to +70°C â40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Unit weight
Approx. 1.8 g .063 oz
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT.
ASCTB212E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
|
▷ |