English
Language : 

GX-3S Datasheet, PDF (9/10 Pages) Panasonic Semiconductor – Cylindrical Compact Inductive Proximity Sensor GX SERIES
819
GX Cylindrical Compact Inductive Proximity Sensor
SERIES
FIBER
SENSORS
PRECAUTIONS FOR PROPER USE
LASER
SENSORS
Distance from surrounding metal
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
• As metal around the sensor may affect the sensing
performance, pay attention to the following points.
Influence of surrounding metal
• The surrounding metal will affect the sensing
performance. Keep the minimum distance specified in the
table below.
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
Model No.
E (mm in)
GX-3S□
3 0.118
E
GX-4S□
3 0.118
GX-5S□
4 0.157
GX-5M□
3 0.118
GX-8M□
4 0.157
GX-8ML□
8 0.315
Embedding of the sensor in metal
• Sensing range may decrease if the sensor is completely
embedded in metal. Especially for the non-threaded type
and the non-shielded type, keep the minimum distance
specified in the table below.
LASER
MARKERS
Model No. F (mm in) G (mm in)
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
F
G
Metal
GX-3S□
GX-4S□
GX-5S□
GX-8ML□
ø12 ø0.472 3 0.118
ø12 ø0.472 3 0.118
ø15.4 ø0.606 5 0.197
ø30 ø1.181 10 0.394
Mutual interference
• When two or more sensors are installed in parallel or face
to face, keep the minimum separation distance specified
below to avoid mutual interference.
Selection
Guide
Amplifier
Built-in
Amplifier-
separated
Face to face mounting
H
Parallel mounting
GX-F/H J
GXL
GL
GX-U/GX-FU/
GX-N
GX
Model No. H (mm in) J (mm in)
GX-3S□
GX-4S□
GX-5S□
GX-5M□
GX-8M□
GX-8ML□
16 0.630 16 0.630
16 0.630 16 0.630
20 0.787 15 0.591
10 0.394 10 0.394
20 0.787 15 0.591
50 1.969 30 1.181
Refer to General precautions.
Sensing range
• The sensing range is specified for the standard sensing
object. With a non-ferrous metal, the sensing range is
obtained by multiplying with the correction coefficient
specified below. Further, the sensing range also changes
if the sensing object is smaller than the standard sensing
object or if the sensing object is plated.
Correction coefficient
Model No.
Metal
Iron
GX-3S□
GX-4S□
1
GX-5M□
1
GX-5S□
GX-8M□
GX-8ML□
1
Stainless steel
(SUS304)
0.65 approx.
0.83 approx.
0.7 approx.
Brass
0.36 approx.
0.61 approx.
0.4 approx.
Aluminum
0.30 approx.
0.58 approx.
0.35 approx.
Others
• Do not use during the initial transient time (10 ms) after
the power supply is switched on.
• Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
• GX-3S□, GX-4S□ and GX-5M□ do not incorporate
a short-circuit protection circuit at the output. Do not
connect them directly to a power supply or a capacitive
load.