English
Language : 

AQ2A2-C1-T5VDC Datasheet, PDF (4/7 Pages) Panasonic Semiconductor – SIL type SSR with 9mm thickness controls up to 3A
AQ8
• 3 A type
Item
Part No.
AQ3A1-C1-
T5VDC
AQ3A1-C2-
T5VDC
AQ3A1-C1-
T12VDC
AQ3A1-C2-
T12VDC
AQ3A1-C1-
T24VDC
AQ3A1-C2-
T24VDC
AQ3A2-C1-
T5VDC
AQ3A2-C2-
T5VDC
AQ3A2-C1-
T12VDC
AQ3A2-C2-
T12VDC
AQ3A2-C1-
T24VDC
AQ3A2-C2-
T24VDC
Input
side
Control voltage
Input impedance
Drop-out voltage
5 V DC
(4 to 6V)
12 V DC
24 V DC
(9.6 to 14.4V) (21.6 to 26.4V)
5 V DC
(4 to 6V)
12 V DC
24 V DC
(9.6 to 14.4V) (21.6 to 26.4V)
Approx. 0.3 kΩ Approx. 0.8 kΩ Approx. 1.8 kΩ Approx. 0.3 kΩ Approx. 0.8 kΩ Approx. 1.8 kΩ
min. 0.5 V
min. 1.2 V
min. 2.4 V
min. 0.5 V
min. 1.2 V
min. 2.4 V
Max. load current
3 A*1
Load
side
Load voltage
Frequency
Repetitive peak
OFF voltage
Non-repetitive
surge current
Max. “OFF-state”
leakage current
Max. “ON-state”
voltage drop
Min. load current
75 to 125 V AC
400 V
2.5 mA/100 V applied
25 mA*3
45 to 65 Hz
80 A*2
1.6 V
75 to 250 V AC
600 V
5 mA/200 V applied
50 mA*3
OFF state dV/dt
50 V/µs
Notes: *1. Refer REFERENCE DATA “1. Characteristics of load current vs. ambient temperature”.
*2. Refer to REFERENCE DATA “2. characteristics of non-repetitive surge current vs. carrying time”.
*3. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
Remarks
The parenthesized values
represent the allowable
voltage ranges
At ambient temperature of
30°C or less
In one cycle at 60 Hz
at 60 Hz
at max. carrying current
At ambient temperature of
80°C
2. Characteristics (Ambient temperature: 20°C 68°F; Input voltage ripple: 1% or less)
Item
Type
Zero-cross type
Random type
Operate time, max.
1/2 cycle of voltage sine wave + 1 ms
1 ms
Release time, max.
Insulation resistance, min.
Breakdown voltage
1/2 cycle of voltage sine wave + 1 ms
109Ω between input and output
3,000 V AC between input and output
Vibration
resistance
Destructive
Functional
10 to 55 Hz at double amplitude of 3 mm
10 to 55 Hz at double amplitude of 3 mm
Shock
resistance
Destructive
Functional
Ambient temperature
Storage temperature
Operational method
Min. 980 m/s2 {100 G}
Min. 980 m/s2 {100 G}
–30°C to +80°C –22°F to +176°F
–30°C to +100°C –22°F to +212°F
Zero-cross (Turn ON and Turn OFF)
Random turn ON, zero-cross turn OFF
Remarks
at 500 V DC
For 1 minute
1 hour for X, Y, Z axis
10 min. for X, Y, Z axis
5 times each for X, Y, Z axis
4 times each for X, Y, Z axis
REFERENCE DATA
1. Characteristics of load current vs. ambient
temperature
Conditions: Natural cooling
2.-(1) Characteristics of non-repetitive surge
current vs. carrying time
(2 A type)
2.-(2) Characteristics of non-repetitive surge
current vs. carrying time
(3 A type)
3.0
3 A type
2.5
2 A type
2.0
1.5
1.0
0.5
0
–30 0 20 40 60 80
Ambient temperature, °C
100
80
60
40
20
0
5 10
50 100
No. of cycles at 60 Hz
100
80
60
40
20
0
5 10
50 100
No. of cycles at 60 Hz
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.