English
Language : 

HP2-AC24V Datasheet, PDF (3/7 Pages) Panasonic Semiconductor – Relay for control panel of 10A (2c/3c/4c) Food processing packing machines
HP
RATING
1. Coil data
1) AC coils
Contact
arrangement
Nominal coil
voltage
2 Form C
3 Form C
4 Form C
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
Nominal operating
current (mA)
50Hz
60Hz
94mA
78mA
46.5mA
39mA
25.3mA
21mA
23.1mA
18mA
12.4mA
11mA
10.6mA 9.5mA
10.0mA 9.0mA
148.7mA 130mA
74.2mA
65mA
36.4mA
32mA
32.5mA 28.5mA
18.2mA
16mA
16.0mA 14.2mA
15.8mA 13.9mA
229mA 200mA
108mA
95mA
57.3mA
50mA
47.6mA
42mA
28.5mA
25mA
23.8mA
21mA
23.3mA 20.5mA
Nominal operating
power (VA)
50Hz
60Hz
2.25VA
1.9VA
2.23VA
1.9VA
2.36VA
2.1VA
2.31VA
2.1VA
2.48VA
2.2VA
2.34VA
2.1VA
2.40VA
2.2VA
3.56VA
3.1VA
3.56VA
3.1VA
3.64VA
3.2VA
3.74VA
3.3VA
3.65VA
3.2VA
3.54VA
3.1VA
3.79VA
3.3VA
5.49VA
4.8VA
5.18VA
4.6VA
5.73VA
5.0VA
5.47VA
4.8VA
5.69VA
5.0VA
5.24VA
4.6VA
5.58VA
4.9VA
Inductance
(H)
50Hz
60Hz
0.753
0.776
3.055
3.106
12.60
12.03
16.70
15.83
48.03
45.81
61.28
57.90
69.00
66.26
0.0494
0.475
1.976
1.899
8.500
8.038
10.79
10.36
33.53
32.10
41.35
39.32
45.94
44.05
0.320
0.309
1.348
1.292
5.348
5.156
7.264
6.953
21.27
20.45
27.75
26.57
30.98
29.75
Pick-up voltage Drop-out voltage
(at 20°C 68°F) (at 20°C 68°F)
Max. applied
voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
2) DC coils (20°C 68°F)
Contact
arrangement
2 Form C
3 Form C
4 Form C
Nominal coil
voltage
12V DC
24V DC
48V DC
100V DC
110V DC
12V DC
24V DC
48V DC
100V DC
110V DC
12V DC
24V DC
48V DC
100V DC
110V DC
Nominal current
(mA)
109mA
54.5mA
26.7mA
14.9mA
15.0mA
120mA
60mA
31mA
15.6mA
14.9mA
127mA
63mA
32.0mA
16.3mA
15.7mA
Nominal operating
power (W)
1.3W
1.3W
1.3W
1.5W
1.7W
1.4W
1.4W
1.5W
1.6W
1.6W
1.5W
1.5W
1.5W
1.6W
1.7W
Coil resistance
(Ω)
110Ω
440Ω
1,800Ω
6,700Ω
7,300Ω
100Ω
400Ω
1,560Ω
6,400Ω
7,450Ω
95Ω
380Ω
1,500Ω
5,950Ω
7,000Ω
Pick-up voltage Drop-out voltage
(at 20°C 68°F) (at 20°C 68°F)
Max. applied
voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
Notes: 1. The nominal current area is ±15% (60Hz) [AC coils],. ±10% (20°C) [DC coils]
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
3. The relay operates in a range of 80% to 110% V of the nominal coil voltage, but ideally, in consideration of temporary voltage fluctuations, it should be operated at
the nominal coil voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the nominal coil voltage, humming will occur and a
large current will flow leading possibly to coil burnout.
4. For use with 200 V DC, connect a 6.7kΩ (10W) resistor, in series, to the 100 V DC relay [3 Form C type is .6.4kΩ (5W); 4 Form C type is .6.2kΩ (10W)].
5. As a general rule, only a pure DC voltage should be used for the coil drive. However, a DC power supply that contains ripples has characteristics that differ from
pure DC. Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e
ASCTB81E 201201-T