English
Language : 

EYP2BN082 Datasheet, PDF (2/8 Pages) Panasonic Semiconductor – Thermal Cutoffs (TCO)
Thermal Cutoffs (TCO)
■ Ratings
● N series
Part No.
Type No. of Rated Functioning Electrical Rating Maximum Holding Maximum
Approved Functioning Temp. ✽2
Operating Temp. : Th✽4 Temp.
Standards Temp. : Tf✽1 (°C)
(°C)
AC/
DC
Volt. Amp.
(V) (A)
Temp. ✽3
(°C)
(°C)
Limit : Tm✽5
(°C)
PES
Approved Safety
Standards
UL CSA VDE BEAB CCC
AC 250 2
60
60
ćććććć
EYP2BN082
N082
86
82±2 AC 125 3
52
56
200
—ć ć ć ć—
DC 50 4
45
50
—ć ć ć ć—
AC 250 2
65
75
ćććććć
EYP2BN099
N099
102
98+–43
AC 125 3
60
70
200
—ć ć ć ć—
DC 50 4
55
65
—ć ć ć ć—
AC 250 2
80
90
ćććććć
EYP2BN109
N109
114
110±3 AC 125 3
76
86
200
—ć ć ć ć—
DC 50 5
65
74
—ć ć ć ć—
AC 250 2
80
90
ćććććć
EYP2BN110
N110
115
110
+3
–2
AC 125 3
76
86
200
—ć ć ć ć—
DC 50 5
65
74
—ć ć ć ć—
AC 250 2
90
100
ćććććć
EYP2BN127
N127
134
129±4 AC 125 3
75
90
200
—ć ć ć ć—
DC 50 4
65
80
—ć ć ć ć—
AC 250 2
100
110
ćććććć
EYP2BN134
N134
139
135±3 AC 125 3
85
100
200
—ć ć ć ć—
DC 50 6
60
70
—ć ć ć ć—
AC 250 2
110
120
ćććććć
EYP2BN143
N143
145
141±2 AC 125 3
105
115
200
—ć ć ć ć—
DC 50 6
80
90
—ć ć ć ć—
Note: (1) For long lead types add the letter “L” at the end op the part number.
(2) The information of the Approved Safety Standards is furnished as of Jan. 2008.
Approved Safety Standards File No. UL/C-UL:E60271, CSA:1687496(LR67163), VDE:481106-1171-0001, BEAB:C1144, CCC:2002010205004249
● F series
Part No.
Type No. of Rated Functioning Electrical Rating Maximum Holding Maximum
Approved Functioning Temp. ✽2
Operating Temp. : Th✽4 Temp.
Approved Safety
Standards
Standards Temp. : Tf✽1 (°C)
(°C)
AC/
DC
Volt. Amp.
(V) (A)
Temp. ✽3
(°C)
(°C)
Limit : Tm✽5
(°C)
PS
E
UL
C-UL
CSA
VDE BEAB CCC
AC 250 1
65
75
ćććććć
EYP1BF101
F101
102
98±3 AC 125 2
60
70
200
—ć ć ć ć—
DC 50 3.5
55
65
—ć ć ć ć—
AC 250 1
80
90
ćććććć
EYP1BF115
F115
115
110
+3
–2
AC 125 2
76
90
200
—ć ć ć ć—
DC 50 4
70
80
—ć ć ć ć—
AC 250 1
90
105
ćććććć
EYP1BF134
F134
134
129+–34
AC 125 2
85
100
200
—ć ć ć ć—
DC 50 4
65
80
—ć ć ć ć—
AC 250 1
100
110
ćććććć
EYP1BF138
F138
139
135±3 AC 125 2
90
105
200
—ć ć ć ć—
DC 50 5
65
70
—ć ć ć ć—
AC 250 1
110
125
ćććććć
EYP1BF145
F145
145
141±2 AC 125 2
110
125
200
—ć ć ć ć—
DC 50 5
80
95
—ć ć ć ć—
Note: (1) For long lead types add the letter “L” at the end op the part number.
(2) The information of the Approved Safety Standards is furnished as of Jan. 2008.
Approved Safety Standards File No. UL/C-UL:E60271, CSA:1709436(LR67163), VDE:481106-1171-0003, BEAB:C1133, CCC:2002010205004248
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Jan. 2008