HAE100
ENVIRONMENTAL SPECIFICATIONS
Parameter
Conditions
Operating case temperature
Over temperature protection
Storage temperature range
Terminal block type
Others
Thermal impedance (1)
Vertical direction by natural convection (20LFM)
Module without assembly option
Heat-sink type with 0.24" Height
Heat-sink type with 0.45" Height
Thermal shock
Vibration
Relative humidity
Min.
-40
-40
-55
Typ.
+115
6.7
5.4
4.7
Max.
+105
+105
+125
U℃℃nit
℃
℃/W
MIL-STD-810F
MIL-STD-810F
5% to 95% RH
EMC SPECIFICATIONS
Parameter
EMI (2)
ESD
Radiated immunity
Fast transient (3)
Surge (3)
Conducted immunity
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Conditions
Air ±8kV and Contact ±6kV
10V/m
±2kV
EN55024 ±2kV
10Vr.m.s
Level
Class A
Class B
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Perf. Criteria A
Note:
1. (1)Thermal test condition with vertical direction by natural convection (20LFM).
(2) The heat-sink is optional and P/N: 7G-0021A-F , 7G-0022A-F , 7G-0023A-F , 7G-0024A-F. Please refer to heat-sink selection guide.
2. The HAE100 series standard module meets EN55022 Class A and Class B with external components.
3. An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
: Recommended 2 pcs of aluminum electrolytic capacitor (Nippon Chemi-con KY series, 220µF/100V) to connect in parallel.
4. CASE GROUNDING Connecting four screw bolts to shield plane will help to reduce the EMI.
5. For further information, please contact with P-DUKE.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
CHARACTERISTIC CURVE
120
100
80
DC/DC module only
Natural convection (20LFM)
100LFM
60
200LFM
300LFM
400LFM
40
500LFM
Mount on 2U iron base-plate
(dimension 19” X 3.5” X 0.063”)
20
Natural convection (20LFM)
Terminal block
Natural convection (20LFM)
0
-40
-20
℃ 0
20 40 60 80 100 120
AMBIENT TEMPERATURE,TA( )
HAE100-48S05 Derating Curve (Note 1)
120
100
80
60
40
Natural convection (20LFM)
100LFM
200LFM
20
300LFM
400LFM
500LFM
0
-40
-20
℃ 0
20 40 60 80 100 120
AMBIENT TEMPERATURE,TA( )
HAE100-48S05 Derating Curve (Note 1)
With 0.24” Height Heat-sink
120
100
80
60
40
Natural convection (20LFM)
100LFM
200LFM
20
300LFM
400LFM
500LFM
0
-40
-20
℃ 0
20 40 60 80 100 120
AMBIENT TEMPERATURE,TA( )
HAE100-48S05 Derating Curve (Note 1)
With 0.45” Height Heat-sink
96
90
84
78
72
66
Iout= 100% F.L
Iout= 50% F.L
Iout= 25% F.L
60
36 40 44 48 52 56 60 64 68 72 75
INPUT VOLTAGE(V)
HAE100-48S05 Efficiency vs. Input Voltage
96
90
84
78
72
66
Vin= 36V
Vin= 48V
Vin= 75V
60
10 20 30 40 50 60 70 80 90 100
% of FULL LOAD
HAE100-48S05 Efficiency vs. Output Load
3
www.PDUKE.com