HAE100-12S3P3 Datasheet, PDF (2/5 Pages) Power Mate Technology Co., LTD – OUTPUT CURRENT UP TO 25A
Model
Number
Input
Range
Output Output Current
Line
Load
Output (4) (5)
Input Current
Eff (4)
Voltage Min. load Full load Regulation Regulation Ripple & Noise No Load (3) Full Load (2) (%)
HAE100-12S3P3 9 – 18 VDC 3.3 VDC 0 mA
25 A
7 mV
10 mV
75 mVp-p
200 mA
7.768 A
90
HAE100-12S05 9 – 18 VDC 5 VDC 0 mA
20 A
10 mV
15 mV
75 mVp-p
210 mA
9.311 A
91
HAE100-12S12 9 – 18 VDC 12 VDC 0 mA
8.4 A
24 mV
30 mV
100 mVp-p
210 mA
9.385A
91
HAE100-12S15 9 – 18 VDC 15 VDC 0 mA
6.7 A
30 mV
38 mV
100 mVp-p
210 mA
9.358A
91
HAE100-12S24 9 – 18 VDC 24 VDC 0 mA
4.2 A
48 mV
48 mV
200 mVp-p
100 mA
9.492A
90
HAE100-12S28 9 – 18 VDC 28 VDC 0 mA
3.6 A
56 mV
56 mV
200 mVp-p
100 mA
9.492A
90
HAE100-12S48 9 – 18 VDC 48 VDC 0 mA
2.1 A
96 mV
72 mV
300 mVp-p
100 mA
9.492A
90
HAE100-24S3P3 18 – 36 VDC 3.3 VDC 0 mA
25 A
7 mV
10 mV
75 mVp-p
90 mA
3.841 A
91
HAE100-24S05 18 – 36 VDC 5 VDC 0 mA
20 A
10 mV
15 mV
75 mVp-p
185 mA
4.554 A
93
HAE100-24S12 18 – 36 VDC 12 VDC 0 mA
8.4 A
24 mV
30 mV
100 mVp-p
185 mA
4.590A
93
HAE100-24S15 18 – 36 VDC 15 VDC 0 mA
6.7 A
30 mV
38 mV
100 mVp-p
185 mA
4.577 A
93
HAE100-24S24 18 – 36 VDC 24 VDC 0 mA
4.2 A
48 mV
48 mV
200 mVp-p
85 mA
4.641A
92
HAE100-24S28 18 – 36 VDC 28 VDC 0 mA
3.6 A
56 mV
56 mV
200 mVp-p
85 mA
4.641A
92
HAE100-24S48 18 – 36 VDC 48 VDC 0 mA
2.1 A
96 mV
72 mV
300 mVp-p
85 mA
4.641A
92
HAE100-48S3P3 36 – 75 VDC 3.3 VDC 0 mA
25 A
7 mV
10 mV
75 mVp-p
80 mA
1.920 A
91
HAE100-48S05 36 – 75 VDC 5 VDC 0 mA
20 A
10 mV
15 mV
75 mVp-p
90 mA
2.277 A
93
HAE100-48S12 36 – 75 VDC 12 VDC 0 mA
8.4 A
24 mV
30 mV
100 mVp-p
90 mA
2.295A
93
HAE100-48S15 36 – 75 VDC 15 VDC 0 mA
6.7 A
30 mV
38 mV
100 mVp-p
90 mA
2.288 A
93
HAE100-48S24 36 – 75 VDC 24 VDC 0 mA
4.2 A
48 mV
48 mV
200 mVp-p
40 mA
2.320A
92
HAE100-48S28 36 – 75 VDC 28 VDC 0 mA
3.6 A
56 mV
56 mV
200 mVp-p
40 mA
2.320A
92
HAE100-48S48 36 – 75 VDC 48 VDC 0 mA
2.1 A
96 mV
72 mV
300 mVp-p
40 mA
2.320A
92
Note
1. BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at 40℃.
MIL-HDBK-217F Notice2 @Ta=25℃, Full load(Ground, Benign, controlled environment).
2. Maximum value at nominal input voltage and full load.
3. Typical value at nominal input voltage and no load.
4. Typical value at nominal input voltage and full load.
5. The ripple and noise of output voltage 48V is measured with a 2.2μF/100V X7R MLCC;
The ripple and noise of other output voltage is measured with a 4.7μF/50V X7R MLCC.
6. The remote ON/OFF control pin voltage is referenced to –Vin. The positive logic and pin length (DIM.) are optional.
To order positive logic ON-OFF control of standard product add the suffix -P (Ex: HAE100-48S05-P).
7. Output voltage is adjustable for 10% trim up or -20% trim down of nominal output voltage by connecting a single resistor between TRIM and
+SENSE pins for trim up or between TRIM and –SENSE pins for trim down. To calculate the value of the resistor RU and RD for a particular output
voltage uses the following equation:
RU
=
⎜⎜⎝⎛
VOUT (100 + Δ%)
1.225Δ%
−
(100 + 2Δ%)
Δ%
⎟⎟⎠⎞KΩ
RD
=
⎜⎛
⎝
100
Δ%
−
2⎟⎞KΩ
⎠
8. Maximum output deviation is +10% inclusive of remote sense. If remote sense is not being used, the +SENSE should be connected to its
corresponding +OUTPUT and likewise the -SENSE should be connected to its corresponding –OUTPUT.
9. Internal fusing is not included, so we suggest to use an input line fuse.
10. Test condition with vertical direction by natural convection (20LFM).
11. Heat-sink is optional and P/N: 7G-0021A-F, 7G-0022A-F, 7G-0023A-F, 7G-0024A-F.
12. The HAE100 series meets EMC characteristics only with external components connected before the input pin to the converter. If customer only
need to meet EN61000-4-4, EN61000-4-5 ,an external input filter capacitor is required
The filter capacitor Power Mate suggest: Nippon chemi-con KY series, 220μF /100V, ESR 48mΩ
13. CASE GROUNDING:When you connect the case pin and the four screw bolts to shield plane, the EMI could be better reduced.
Page 2 of 5 Issued Date:2009/01/13