English
Language : 

LUWH9QP-5M8M-HNJN-1 Datasheet, PDF (11/24 Pages) OSRAM GmbH – SMD epoxy package
Version 1.10 (not for new design)
LUW H9QP
Max. Permissible Forward Current
Max. zulässiger Durchlassstrom
IF = f (T)
IF [mA] 1300
LUW H9QP.CE
1200
1100
1000
900
800
700
: TS
600
500
400
300
200
100
Do not use below 100 mA
0
0 20 40 60 80 100 120 140
TS [°C]
Permissible Pulse Handling Capability
Zulässige Impulsbelastbarkeit IF = f(tp)
D: Duty cycle, TS = 25 °C
IF [A]
2.6
2.4
2.2
:D=1
: D = 0.5
: D = 0.2
: D = 0.1
: D = 0.05
: D = 0.02
: D = 0.01
: D = 0.005
2.0
1.8
1.6
1.4
1.2
10-5
10-4
10-3
0.01
Pulse Time t{p} [s]
Permissible Pulse Handling Capability
Zulässige Impulsbelastbarkeit IF = f(tp)
D: Duty cycle, TS = 125 °C
IF [A] 2.6
2.4
2.2
:D=1
: D = 0.5
: D = 0.2
: D = 0.1
: D = 0.05
: D = 0.02
: D = 0.01
: D = 0.005
2.0
1.8
1.6
1.4
1.2
1.0
0.8
10-5
10-4
10-3
0.01
Pulse Time tp [s]
2015-12-10