CAT9554, CAT9554A
FUNCTIONAL DESCRIPTION
The CAT9554 and CAT9554A general purpose input/
output (GPIO) peripherals provide up to eight I/O
ports, controlled through an I²C compatible serial
interface
The CAT9554/54A support the I²C Bus data
transmission protocol. This I²C Bus protocol defines
any device that sends data to the bus to be a
transmitter and any device receiving data to be a
receiver. The transfer is controlled by the Master
device which generates the serial clock and all
START and STOP conditions for bus access. The
CAT9554/9554A operate as a Slave device. Both the
Master device and Slave device can operate as either
transmitter or receiver, but the Master device controls
which mode is activated.
I²C BUS PROTOCOL
The features of the I²C bus protocol are defined as
follows:
(1) Data transfer may be initiated only when the bus
is not busy.
(2) During a data transfer, the data line must remain
stable whenever the clock line is high. Any
changes in the data line while the clock line is
high will be interpreted as a START or STOP
condition (Figure 5).
START AND STOP CONDITIONS
The START Condition precedes all commands to the
device, and is defined as a HIGH to LOW transition of
SDA when SCL is HIGH. The CAT9554/9554A
monitors the SDA and SCL lines and will not respond
until this condition is met.
A LOW to HIGH transition of SDA when SCL is HIGH
determines the STOP condition. All operations must
end with a STOP condition.
DEVICE ADDRESSING
After the bus Master sends a START condition, a slave
address byte is required to enable the CAT9554/9554A
for a read or write operation. The four most significant
bits of the slave address are fixed as binary 0100 for
the CAT9554 (Figure 6) and as 0111 for the CAT9554A
(Figure 7). The CAT9554/9554A uses the next three
bits as address bits.
The address bits A2, A1 and A0 are used to select
which device is accessed from maximum eight
devices on the same bus. These bits must compare to
their hardwired input pins. The 8th bit following the 7-
bit slave address is the R/¯W¯ bit that specifies whether
a read or write operation is to be performed. When
this bit is set to “1”, a read operation is initiated, and
when set to “0”, a write operation is selected.
Following the START condition and the slave address
byte, the CAT9554/9554A monitors the bus and
responds with an acknowledge (on the SDA line) when
its address matches the transmitted slave address. The
CAT9554/9554A then performs a read or a write
operation depending on the state of the R/¯W¯ bit.
SCL
SDA
START
CONDITION
STOP
CONDITION
Figure 5. START/STOP Condition
SLAVE ADDRESS
0 1 0 0 A2 A1 A0 R/W
FIXED
PROGRAMMABLE
HARDWARE
SELECTABLE
Figure 6. CAT9554 Slave Address
SLAVE ADDRESS
0 1 1 1 A2 A1 A0 R/W
FIXED
PROGRAMMABLE
HARDWARE
SELECTABLE
Figure 7. CAT9554A Slave Address