English
Language : 

CYIL2SM1300-EVAL Datasheet, PDF (6/41 Pages) ON Semiconductor – LUPA 1300-2: High Speed CMOS Image Sensor
CYIL2SM1300AA
Table 4. Power Supply Ratings [3, 4, 5] (continued)
Boldface limits apply for TA=TMIN to TMAX, all other limits TA=+25°C. Clock = 315 MHz
Symbol Power Supply
Parameter
Condition
VBUF, GNDBUF Buffer Supply
Operating voltage
Dynamic Current
Clock enabled, lux=0
Peak Current
Clock enabled, lux=0
Standby current
shutdown mode, lux=0
VSAMPLE,
GNDSAMPLE
Sampling
Operating voltage
Circuitry Supply Dynamic Current
Clock enabled, lux=0
Peak Current
Clock enabled, lux=0
Standby current
Shutdown mode, lux=0
VRES
Reset Supply
Operating voltage
Dynamic Current
Clock enabled, lux=0
Peak Current
Clock enabled, lux=0
Standby current
Shutdown mode, lux=0
VRES_AB
Antiblooming
Supply
Operating voltage
Dynamic Current
Clock enabled, lux=0
Peak Current following
edge reset
Clock enabled, lux=0
Standby current
Shutdown mode, lux=0
VRES_DS
Reset Dual
Slope Supply
Operating voltage
Dynamic Current
Clock enabled, lux=0
Peak Current
Clock enabled, lux=0
VRES_TS
Reset Triple
Slope Supply
Operating voltage
Dynamic Current
Clock enabled, lux=0
Peak Current
Clock enabled, lux=0
VMEM_L
Memory
Element low
level supply
Operating voltage
Dynamic Current
Clock enabled, lux=0
Peak Current during FOT Clock enabled, lux=0
Peak Current during FOT Clock enabled, bright
VMEM_H
Memory
Element high
level supply
Operating voltage
Dynamic Current
Clock enabled, lux=0
Peak Current during FOT Clock enabled, lux=0
VPRECH
Pre_charge
Driver Supply
Operating voltage
Dynamic Current
Clock enabled, lux=0
Peak Current during FOT Clock enabled, lux=0
Peak Current during FOT Clock enabled, lux=bright
Min
-5%
-5%
-5%
-10%
-5%
-5%
-5%
-5%
-10%
Typ Max Units
2.5 +5%
V
30
50
mA
85
mA
0.1
mA
2.5 +5% V
2
mA
42
mA
1
mA
3.5 +5%
V
2
15
mA
65
mA
2
mA
0.7 +10% V
1
mA
50
mA
1
mA
2.5 +5% V
0.4
3
mA
36
mA
1.8 +5% V
0.3
2
mA
14
mA
2.5 +5% V
0.2
1
mA
62
mA
30
mA
3.3 +5% V
1
mA
45
mA
0.7 +10% V
0.3
3
mA
32
mA
25
mA
Every module in the image sensor has its own power supply and
ground. The grounds can be combined externally, but not all
power supply inputs may be combined. Some power supplies
must be isolated to reduce electrical crosstalk and improve
shielding, dynamic range, and output swing. Internal to the
image sensor, the ground lines of each module are kept separate
to improve shielding and electrical crosstalk between them.
The LUPA 1300-2 contains circuitry to protect the inputs against
damage due to high static voltages or electric fields. However,
take normal precautions to avoid voltages higher than the
maximum rated voltages in this high impedance circuit. Unused
inputs must always be tied to an appropriate logic level, for
example, VDD or GND. All cap_xxx pins must be connected to
ground through a 100 nF capacitor.
The recommended combinations of supplies are:
■ Analog group of +2.5V supply: VSAMPLE, VRES_DS, VMEM_L,
VADC, Vpix, VANA, VBUF
■ Digital Group of +2.5V supply: VDIG, VLVDS