English
Language : 

NSPM1041B Datasheet, PDF (5/7 Pages) ON Semiconductor – Transient Voltage Suppressors
NSPM1041B
Transmission Line Pulse (TLP) Measurement
Transmission Line Pulse (TLP) provides current versus
voltage (I−V) curves in which each data point is obtained
from a 100 ns long rectangular pulse from a charged
transmission line. A simplified schematic of a typical TLP
system is shown in Figure 8. TLP I−V curves of ESD
protection devices accurately demonstrate the product’s
ESD capability because the 10s of amps current levels and
under 100 ns time scale match those of an ESD event. This
is illustrated in Figure 9 where an 8 kV IEC 61000−4−2
current waveform is compared with TLP current pulses at
8 A and 16 A. A TLP I−V curve shows the voltage at which
the device turns on as well as how well the device clamps
voltage over a range of current levels. For more information
on TLP measurements and how to interpret them please
refer to AND9007/D.
L
50 W Coax
Cable
S Attenuator
÷
50 W Coax
Cable
10 MW
IM VM
VC
DUT
Oscilloscope
Figure 8. Simplified Schematic of a Typical TLP
System
Figure 9. Comparison Between 8 kV IEC 61000−4−2 and 8 A and 16 A TLP Waveforms
www.onsemi.com
5