CM1223_12 Datasheet, PDF (4/13 Pages) ON Semiconductor – Capacitance ESD Protection Arrays with Backdrive Protection | |||
|
◁ |
CM1223
SPECIFICATIONS
Table 2. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Units
Operating Supply Voltage (VP â VN)
Operating Temperature Range
6.0
V
â40 to +85
°C
Storage Temperature Range
â65 to +150
°C
DC Voltage at any channel input
(VN â 0.5) to (VP + 0.5)
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 3. STANDARD OPERATING CONDITIONS
Parameter
Operating Temperature Range
Package Power Rating
SOT143â4 Package (CM1223â02SR)
SOT23â5 Package (CM1223â02SO)
SOT23â6 Package (CM1223â04SO)
MSOPâ10 Package (CM1223â04MR)
MSOPâ10 Package (CM1223â08MR)
Rating
â40 to +85
225
225
225
400
400
Units
°C
mW
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Note1)
Symbol
Parameter
Conditions
Min Typ Max
VP
IP
VSCL
Operating Supply Voltage (VPâVN)
Operating Supply Current
Signal Clamp Voltage
Positive Transients
Negative Transients
(VPâVN) = 3.3 V
IF = 8 mA; TA = 25°C
3.3
5.5
8.0
6.7
8.2
0.60 0.80
ILEAK
CIN
DCIN
CMUTUAL
Channel Leakage Current
Channel Input Capacitance
Channel Input Capacitance Matching
Mutual Capacitance between signal pin
and adjacent signal pin
TA = 25°C; VP = 5 V, VN = 0 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
±0.1 ±1.0
1.0
1.5
0.02
0.11
VESD
VCL
ESD Protection â Peak Discharge
Voltage at any channel input, in system
a) Contact discharge per
IEC 61000â4â2 standard
b) Human Body Model,
MILâSTDâ883, Method 3015
Channel Clamp Voltage
Positive Transients
Negative Transients
TA = 25°C; (Notes 3 and 4)
TA = 25°C; (Notes 2 and 4)
TA = 25°C, IPP = 1A, tP = 8/20 mS
(Note 4)
±8
±15
+8.8
â1.4
RDYN Dynamic Resistance
TA = 25°C, IPP = 1A, tP = 8/20 mS
Positive Transients
Any I/O pin to Ground
0.7
Negative Transients
(Note 4)
0.4
1. All parameters specified at TA = â40°C to +85°C unless otherwise noted.
2. Human Body Model per MILâSTDâ883, Method 3015, CDischarge = 100 pF, RDischarge = 1.5 kW, VP = 3.3 V, VN grounded.
3. Standard IEC 61000â4â2 with CDischarge = 150 pF, RDischarge = 330 W, VP = 3.3 V, VN grounded.
4. These measurements performed with no external capacitor on VP (VP floating).
Units
V
mA
V
mA
pF
pF
pF
kV
V
W
http://onsemi.com