English
Language : 

CAT5133ZI-10-GT3 Datasheet, PDF (4/10 Pages) ON Semiconductor – 16 Volt Digitally Programmable Potentiometer with 128 Taps and an Increment Decrement Interface
CAT5133
RECOMMENDED OPERATING CONDITIONS
VCC = +2.7V to +5.5V
V+ = +8.0V to +16.0V
Operating Temperature Range: -40°C to +85°C
POTENTIOMETER CHARACTERISTICS
(Over recommended operating conditions unless otherwise stated.)
Symbol Parameter
Test Conditions
RPOT
RPOT
RPOT
RTOL
Potentiometer Resistance (10kΩ)
Potentiometer Resistance (50kΩ)(7)
Potentiometer Resistance (100kΩ)(7)
Potentiometer Resistance Tolerance
Power Rating
25ºC
IW Wiper Current
RW Wiper Resistance
VTERM Voltage on RW , RH or RL
IW = +1mA @ V+ = 12V
IW = +1mA @ V+ = 8V
GND = 0V;
V+ = 8V to 16V
RES Resolution
ALIN Absolute Linearity(2)
RLIN Relative Linearity(3)
TCRPOT Temperature Coefficient of RPOT
TCRatio Ratiometric Temperature Coefficient
CH/CL/C Potentiometer Capacitances
fc Frequency Response
VW(n)(actual)
-
V (5),
W(n)(expected)
(6)
VW(n+1) - [VW(n) +LSB](5), (6)
(1)
(1)
(1)
RPOT = 50kΩ
Min
GND
Limits
Typ
10
50
100
70
110
0.78
±300
10/10/25
0.4
Max
±20
50
±3
150
200
V+
±1
±0.5
30
Units
kΩ
kΩ
kΩ
%
mW
mA
Ω
Ω
V
%
LSB(4)
LSB(4)
ppm/°C
ppm/°C
pF
MHz
Notes:
(1) This parameter is tested initially and after a design or process change that affects the parameter.
(2) Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
(3) Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer.
(4) LSB = (RHM - RLM)/127; where RHM and RLM are the highest and lowest measured values on the wiper terminal.
(5) n = 1, 2, ..., 127.
(6) V+ @ RH; 0V @ RL; VW measured @ RW, with no load.
(7) Contact factory for availability on this version of the CAT5133.
Doc. No. MD-2125 Rev. D
4
© 2008 SCILLC. All rights reserved.
Characteristics subject to change without notice