English
Language : 

CAT25256LI-G Datasheet, PDF (4/20 Pages) ON Semiconductor – 256-Kb SPI Serial CMOS EEPROM
CAT25256
Table 6. A.C. CHARACTERISTICS − MATURE PRODUCT
(TA = −40°C to +85°C (Industrial) and TA = −40°C to +125°C (Extended).) (Notes 6, 9)
VCC = 1.8 V − 5.5 V / −405C to +855C
VCC = 2.5 V − 5.5 V / −405C to +1255C
VCC = 2.5 V − 5.5 V
−405C to +855C
Symbol
Parameter
Min
Max
Min
Max
Units
fSCK
tSU
Clock Frequency
Data Setup Time
DC
5
DC
10
MHz
40
20
ns
tH
Data Hold Time
40
tWH
SCK High Time
75
tWL
SCK Low Time
75
tLZ
HOLD to Output Low Z
tRI (Note 7)
Input Rise Time
tFI (Note 7)
Input Fall Time
tHD
HOLD Setup Time
0
tCD
HOLD Hold Time
10
tV
Output Valid from Clock Low
tHO
Output Hold Time
0
tDIS
Output Disable Time
tHZ
HOLD to Output High Z
tCS
CS High Time
140
20
ns
40
ns
40
ns
50
25
ns
2
2
ms
2
2
ms
0
ns
10
ns
75
40
ns
0
ns
50
20
ns
100
25
ns
70
ns
tCSS
CS Setup Time
30
15
tCSH
CS Hold Time
30
15
tCNS
CS Inactive Setup Time
20
15
tCNH
CS Inactive Hold Time
20
15
tWPS
WP Setup Time
10
10
tWPH
WP Hold Time
100
60
tWC (Note 8)
Write Cycle Time
5
6. AC Test Conditions:
Input Pulse Voltages: 0.3 VCC to 0.7 VCC
Input rise and fall times: ≤ 10 ns
Input and output reference voltages: 0.5 VCC
Output load: current source IOL max/IOH max; CL = 50 pF
7. This parameter is tested initially and after a design or process change that affects the parameter.
ns
ns
ns
ns
ns
ns
5
ms
8. tWC is the time from the rising edge of CS after a valid write sequence to the end of the internal write cycle.
9. All Chip Select (CS) timing parameters are defined relative to the positive clock edge (Figure 2). tCSH timing specification is valid
for die revision C and higher. The die revision C is identified by letter “C” or a dedicated marking code on top of the package. For
previous product revision (Rev. B) the tCSH is defined relative to the negative clock edge.
Table 7. POWER−UP TIMING (Notes 7, 10)
Symbol
Parameter
Max
tPUR
Power−up to Read Operation
1
tPUW
Power−up to Write Operation
1
10. tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated.
Units
ms
ms
http://onsemi.com
4