RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
Typ
Max
Units
VCC Supply Voltage
Operating
Data Retention Only
V
2.0
3.3
3.6
1.5
3.3
3.6
VI
Input Voltage
VO Output Voltage
(HIGH or LOW State)
(3âState)
0
5.5
V
V
0
VCC
0
5.5
IOH HIGH Level Output Current, VCC = 3.0 V â 3.6 V
â24
mA
IOL LOW Level Output Current, VCC = 3.0 V â 3.6 V
24
mA
IOH HIGH Level Output Current, VCC = 2.7 V â 3.0 V
â12
mA
IOL LOW Level Output Current, VCC = 2.7 V â 3.0 V
12
mA
TA
Operating FreeâAir Temperature
â40
+85
°C
Dt/DV Input Transition Rise or Fall Rate, VIN from 0.8 V to 2.0 V, VCC = 3.0 V
0
10
ns/V
Functional operation above the stresses listed in the Recommended Operating Ranges is not implied. Extended exposure to stresses beyond
the Recommended Operating Ranges limits may affect device reliability.
DC ELECTRICAL CHARACTERISTICS
TA = â40°C to +85°C
Symbol
Characteristic
Condition
Min
Max
Units
VIH HIGH Level Input Voltage (Note 2)
VIL LOW Level Input Voltage (Note 2)
VOH HIGH Level Output Voltage
VOL LOW Level Output Voltage
IOZ 3âState Output Current
2.7 V ⤠VCC ⤠3.6 V
2.7 V ⤠VCC ⤠3.6 V
2.7 V ⤠VCC ⤠3.6 V; IOH = â100 mA
VCC = 2.7 V; IOH = â12 mA
VCC = 3.0 V; IOH = â18 mA
VCC = 3.0 V; IOH = â24 mA
2.7 V ⤠VCC ⤠3.6 V; IOL = 100 mA
VCC = 2.7 V; IOL = 12 mA
VCC = 3.0 V; IOL = 16 mA
VCC = 3.0 V; IOL = 24 mA
VCC = 3.6 V, VIN = VIH or VIL,
VOUT = 0 to 5.5 V
2.0
V
0.8
V
VCC â 0.2
V
2.2
2.4
2.2
0.2
V
0.4
0.4
0.55
±5
mA
IOFF Power Off Leakage Current
VCC = 0, VIN = 5.5 V or VOUT = 5.5 V
10
mA
IIN
Input Leakage Current
VCC = 3.6 V, VIN = 5.5 V or GND
±5
mA
ICC Quiescent Supply Current
VCC = 3.6 V, VIN = 5.5 V or GND
10
mA
DICC Increase in ICC per Input
2.3 ⤠VCC ⤠3.6 V; VIH = VCC â 0.6 V
500
mA
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product