English
Language : 

CM1213_13 Datasheet, PDF (3/9 Pages) ON Semiconductor – 6 and 8-Channel Low Capacitance ESD Protection Arrays
CM1213
SPECIFICATIONS
Table 2. ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
Units
Operating Supply Voltage (VP − VN)
Operating Temperature Range
6.0
V
−40 to +85
°C
Storage Temperature Range
−65 to +150
°C
DC Voltage at any channel input
(VN − 0.5) to (VP + 0.5)
V
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 3. STANDARD OPERATING CONDITIONS
Parameter
Operating Temperature Range
Package Power Rating
MSOP−8 Package (CM1213−06MR)
MSOP−10 Package (CM1213−08MR)
SOIC−8 Package (CM1213−06SM)
Rating
−40 to +85
400
400
600
Units
°C
mW
Table 4. ELECTRICAL OPERATING CHARACTERISTICS (Note 1)
Symbol
Parameter
Conditions
Min Typ Max
VP
Operating Supply Voltage (VP−VN)
IP
Operating Supply Current
VF
Diode Forward Voltage
Top Diode
Bottom Diode
(VP−VN) = 3.3 V
IF = 8 mA; TA = 25°C
3.3
5.5
8.0
0.60 0.80 0.95
0.60 0.80 0.95
ILEAK
CIN
DCIN
CMUTUAL
Channel Leakage Current
Channel Input Capacitance
Channel Input Capacitance Matching
Mutual Capacitance between signal pin
and adjacent signal pin
TA = 25°C; VP = 5 V, VN = 0 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
At 1 MHz, VP = 3.3 V, VN = 0 V, VIN = 1.65 V
±0.1 ±1.0
1.0
1.5
0.02
0.11
VESD
ESD Protection
Peak Discharge Voltage at any
channel input, in system
Contact discharge per
TA = 25°C (Notes 3 and 4)
±8
IEC 61000−4−2 standard
VCL
Channel Clamp Voltage
Positive Transients
Negative Transients
TA = 25°C, IPP = 1 A, tP = 8/20 mS
(Note 4)
+8.8
−1.4
RDYN Dynamic Resistance
IPP = 1 A, tP = 8/20 mS
Positive Transients
Any I/O pin to Ground (Note 4)
0.7
Negative Transients
0.4
1. All parameters specified at TA = −40°C to +85°C unless otherwise noted.
2. Human Body Model per MIL−STD−883, Method 3015, CDischarge = 100 pF, RDischarge = 1.5 KW, VP = 3.3 V, VN grounded.
3. Standard IEC 61000−4−2 with CDischarge = 150 pF, RDischarge = 330 W, VP = 3.3 V, VN grounded.
4. These measurements performed with no external capacitor on VP (VP floating).
Units
V
mA
V
mA
pF
pF
pF
kV
V
W
http://onsemi.com
3