English
Language : 

CAT4109 Datasheet, PDF (3/12 Pages) ON Semiconductor – 3-Channel Constant-Current RGB LED Driver with Individual PWM Dimming
CAT4109
Table 3. ELECTRICAL OPERATING CHARACTERISTICS (Min and Max values are over recommended operating conditions
unless specified otherwise. Typical values are at VDD = 5.0 V, TAMB = 25°C.)
Symbol
Name
Conditions
Min
Typ
Max
Units
DC CHARACTERISTICS
IDD1
IDD2
IDD3
IDD4
ISHDN
ILKG
ROE
VOE_IH
VOE_IL
Supply Current Outputs Off
Supply Current Outputs Off
Supply Current Outputs On
Supply Current Outputs On
Shutdown Current
LED Output Leakage
OE Pull−down Resistance
OE Logic High Level
OE Logic Low Level
VLED = 5 V, RSET = 24.9 kW
VLED = 5 V, RSET = 5.23 kW
VLED = 0.5 V, RSET = 24.9 kW
VLED = 0.5 V, RSET = 5.23 kW
VOE = 0 V
VLED = 5 V, Outputs Off
2
5
mA
4
10
mA
2
5
mA
4
10
mA
1
mA
−1
1
mA
140
190
250
kW
1.3
V
0.4
VPWM_IH PWMx Logic High Level
VPWM_IL PWMx Logic Low Level
0.7 x VDD
V
0.3 x VDD
IIL
VRSETx
TSD
THYS
ILED/IRSET
VUVLO
Logic Input Leakage Current (PWMx)
RSETx Regulated Voltage
Thermal Shutdown
Thermal Hysteresis
RSET to LED Current Gain Ratio
Undervoltage Lockout (UVLO)
Threshold
VPWMx = VDD or GND
100 mA LED Current
−5
0
5
mA
1.17
1.2
1.23
V
150
°C
20
°C
400
1.8
V
Table 4. RECOMMENDED TIMING (Min and Max values are over recommended operating conditions unless specified otherwise.
Typical values are at VDD = 5.0 V, TAMB = 25°C.)
Symbol
Name
Conditions
Min
Typ
Max
Units
tPS
Turn−On time, OE rising to ILED from Shutdown ILED = 100 mA
tP1
Turn−On time, OE or PWMx rising to ILED
ILED = 100 mA
tP2
Turn−Off time, OE or PWMx falling to ILED
ILED = 100 mA
tR
LED rise time
ILED = 100 mA
1.4
ms
600
ns
300
ns
300
ns
tF
tLO
tHI
tPWRDWN
LED fall time
OE low time
OE high time
OE low time to shutdown delay
ILED = 100 mA
300
ns
1
ms
5
ms
4
8
ms
http://onsemi.com