KAI-16070 Datasheet, PDF (20/48 Pages) ON Semiconductor – Interline CCD Image Sensor | |||
|
◁ |
KAIâ16070
OPERATION
Table 13. ABSOLUTE MAXIMUM RATINGS
Description
Symbol
Minimum
Maximum
Units
Notes
Operating Temperature
Humidity
TOP
â50
+70
°C
1
RH
+5
+90
%
2
Output Bias Current
Iout
60
mA
3
Offâchip Load
CL
10
pF
Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality
should not be assumed, damage may occur and reliability may be affected.
1. Noise performance will degrade at higher temperatures.
2. T = 25°C. Excessive humidity will degrade MTTF.
3. Total for all outputs. Maximum current is â15 mA for each output. Avoid shorting output pins to ground or any low impedance source during
operation. Amplifier bandwidth increases at higher current and lower load capacitance at the expense of reduced gain (sensitivity).
Table 14. ABSOLUTE MAXIMUM VOLTAGE RATINGS BETWEEN PINS AND GROUND
Description
Minimum
Maximum
Units
VDDa, VOUTa
â0.4
17.5
V
RDa
â0.4
15.5
V
V1B, V1T
ESD â 0.4
ESD + 24.0
V
V2B, V2T, V3B, V3T, V4B, V4T
ESD â 0.4
ESD + 14.0
V
FDGab, FDGcd
ESD â 0.4
ESD + 14.0
V
H1Sa, H1Ba, H2Sa, H2Ba, H2SLa, Ra, OGa
ESD â 0.4
ESD + 14.0
V
ESD
â10.0
0.0
V
SUB
â0.4
+40.0
V
1. a denotes a, b, c or d
2. Refer to Application Note Using Interline CCD Image Sensors in High Intensity Visible Lighting Conditions.
Notes
1
1
1
2
KAIâ29050 Compatibility
The KAIâ16070 is pinâforâpin compatible with a camera
designed for the KAIâ29050 image sensor with the
following accommodations:
1. To operate in accordance with a system designed
for KAIâ29050, the target substrate voltage should
be set to be 2.0 V higher than the value recorded
on the KAIâ16070 shipping container. This setting
will cause the charge capacity to be limited to
20 Keâ (or 660 mV).
2. On the KAIâ16070, pins 19 (R2ab) and 55 (R2cd)
should be left floating per the KAIâ29050 Device
Performance Specification.
3. The KAIâ16070 will operate in only the high gain
mode (33 mV/e).
4. All timing and voltages are taken from the
KAIâ29050 specification sheet.
5. The number of horizontal and vertical CCD clock
cycles is reduced as appropriate.
6. In addition, if the intent is to operate the
KAIâ16070 image sensor in a camera designed for
the KAIâ29050 sensor that has been modified to
accept and process the full 40,000 eâ (1,320 mV)
output, the following changes to the following
voltage bias must be made:
Voltage Bias Differences
Pins 10, 28, 46, and 64
KAIâ29050
12.0 V per the
specification
KAIâ16070
Increase this
value to 12.6 V
NOTE: To make use of the low gain mode or dual gain
mode the KAIâ16070 voltages and timing
specification must be used.
www.onsemi.com