English
Language : 

KAC-06040 Datasheet, PDF (11/43 Pages) ON Semiconductor – ESD6100
Dark Current vs. Temperature
KAC−06040
NOTE: “Dbl” denotes an approximate doubling temperature for the dark current for the displayed temperature range.
Figure 8. Dark Current vs. Temperature
Power vs. Frame Rate
The most effective method to set the frame rate is to use
vertical blanking (Register 01F1h). Unnecessary chip
operations are suspended during vertical blanking
conserving significant power consumption and also
minimizing the image storage time on the storage node when
in Global Shutter Operation. Tri−scan can reach higher
frame rates, but consumes more power at all frame rates. It
is recommended use Dual−Scan unless the frame rate
required can only be reached with Tri−Scan. The LVDS
clock is 1/2 the PLL2 clock frequency.
Figure 9. Dual−Scan Power vs. Frame Rate, 10 bit Mode
www.onsemi.com
11