V
V
Characteristics
Operating speed
0.1 mm to 1 m/s (pin plunger models)
Operating frequency
Mechanical: 600 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
(initial value)
15 mΩ max.
Dielectric strength
(see note 2)
1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
V-21, V-16, and V-11 models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts
and ground, and between each terminal and non-current-carrying metal parts
V-15 and V-10 models: 1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and
ground, and between each terminal and non-current-carrying metal parts
Vibration resistance
(see note 3)
Shock resistance
(see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s2 {approx. 100G} max.
Malfunction: V-21/V-16/V-15: 300 m/s2 {approx. 30G} max.
V-11/V-10:
200 m/s2 {approx. 20G} max.
Durability
(see note 4)
Mechanical: 50,000,000 operations min. (60 operations/min)
Electrical: V-21/V-16/V-15: 100,000 operations min. (30 operations/min)
(V-15 heat resistive: 20,000 operation min. (30 operations/min))
V-11/V-10:
300,000 operations min. (30 operations/min)
(V-10 heat resistive: 50,000 operation min. (30 operations/min))
Degree of protection
IEC IP40
Degree of protection against Class I
electric shock
Proof tracking index (PTI)
175
Ambient operating
temperature
–25°C to 80°C (at ambient humidity of 60% max.) (with no icing)
–25°C to 150°C for heat-resistive model (at ambient humidity of 60% max.) (with no icing)
Ambient operating humidity 85% max. (for 5°C to 35°C)
Weight
Approx. 6.2 g (pin plunger models)
Note: 1. The data given above are initial values.
2. The dielectric strength values shown in the table are for models with a Separator.
3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models,
they apply at the total travel position.
4. For testing conditions, contact your OMRON sales representative.
Approved Standards
Consult your OMRON sales representative for specific models with standard approvals.
UL1054 (File No. E41515)/CSA C22.2 No. 55 (File NO. lR21642)
Rated voltage
125 VAC
250 VAC
V-21
21 A, 1/2 HP
V-16
16 A, 1/2 HP
V-15
15 A, 1/2 HP
V-11
11 A, 1/3 HP
V-10
10 A, 1/3 HP
125 VDC
250 VDC
0.6 A
0.3 A
0.6 A
0.3 A
0.6 A
0.3 A
0.6 A
0.3 A
0.6 A
0.3 A
EN61058-01 (File No. 129608, VDE approval)
Rated
voltage
250 VAC
V-21
20 (4) A
V-16
16 (4) A
V-11
11 (3) A
Testing conditions: 5E4 (50,000 operations), T105 (0°C to 105°C)
EN61058-1 (File No. T9451451, TÜV Rheinland
approval)
Rated voltage
250 VAC
250 VDC
V-15
15 A
0.3 A
V-10
10 A
0.3 A
Testing conditions: 5E4 (50,000 operations), T85 (0°C to 85°C)