G2R-14-DC5 Datasheet, PDF (8/14 Pages) Omron Electronics LLC – 1General purpose power Relays of single-pole10 A and double-pole 5 A.
G2R
G2RK-1A, G2RK-1
1,000
500
300
100
250 VAC/30 VDC
50
resistive load
30
250 VAC inductive load
(cosφ = 0.4)
10
5
30 VDC inductive load (L/R = 7ms)
3
G2RK-2A, G2RK-2
1,000
500
300
250 VAC/30 VDC
resistive load
100
30 VDC inductive load
(L/R = 7ms)
50
250 VAC inductive load
30
(cosφ = 0.4)
10
5
3
PCB Power Relay
0
1
2 2.5 3 3.5 4
5
6
Switching current (A)
Fully Sealed Relays
G2R-14, G2R-1A4
1,000
500
300
100
50
G
30
2
R
10
5
3
250 VAC/30 VDC
resistive load
250 VAC inductive load
(cosφ = 0.4)
30 VDC inductive load (L/R = 7ms)
0
1 1.5 2 2.5 3
4
Switching current (A)
G2R-24, G2R-2A4
1,000
500
300
30 VDC inductive load (L/R = 7ms)
100
50
250 VAC/30 VDC
30
resistive load
10
5
250 VAC inductive load
(cosφ = 0.4)
3
G2R-1Z4, G2R-1AZ4
1,000
500
300
30 VDC inductive load (L/R = 7ms)
100
50
250 VAC/30 VDC
resistive load
30
10
5
250 VAC inductive load
(cosφ = 0.4)
3
0
2
4
6
8
10 12
Switching current (A)
● Ambient Temperature vs. Maximum
Coil Voltage
250
200
DC coil
170
150
140
110
100
AC coil
50
0
1 1.5 2 2.5 3
4
5
6
Switching current (A)
● Ambient Temperature vs. Must
Operate and Must Release Voltage
G2R-1
100
Sample: G2R-1
Number of Relays: 5 pcs
Must operate voltage
Must release voltage
80
max.
X
60
min.
40
max.
X
20
min.
0
1
2
3
4
5
6
Switching current (A)
G2R-2
100
Sample: G2R-2
Number of Relays: 5 pcs
80
60
Must operate voltage
Must release voltage
max.
X
min.
40
max.
X
20
min.
0
−25 20 30 40 50 60 70 80 90 100
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum
value in a varying range of operating power voltage,
not a continuous voltage.
0
−60 −40 −20 0
20 40 60 80
Ambient temperature (°C)
● Shock Malfunction
G2R-1 Number of Relays: 5 pcs
G2R-2 Number of Relays: 5 pcs
SPST-NO (1a) Y 1,000
SPST-NC (1c)
800
X
600
400
200
200
400
Z
600
800
1,000
Y'
Test Conditions:
Shock is applied in
±X, ±Y, and ±Z
directions three times
Z' each with and without
energizing the Relays
to check the number
of contact
malfunctions.
Requirement:
200 m/s2 when
energized; 100m/s2
when de-energized
X'
Shock direction
X
X'
Y
Unit: m/s2
Z
Z'
Y'
SPST-NO (1a) Y 1,000
SPST-NC (1c)
800
X
600
400
200
270
200
400
Z
600
800
1,000
Y'
Test Conditions:
Shock is applied in
±X, ±Y, and ±Z
directions three times
Z' each with and without
energizing the
Relays to check the
number of contact
malfunctions.
Requirement:
200 m/s2 when
energized; 100m/s2
when de-energized
X'
Shock direction
X
X'
Y
Z
Unit: m/s2
Z'
Y'
0
−60 −40 −20 0
20 40 60 80
Ambient temperature (°C)
● Keep-power decrement with time
G2RK-1
160 Number of Relays: 50 pcs
Measurement: after the relay kept static by
140 applying a rated voltage, leave the relay at room
temperature of 20°C to 30°C, and high temperature
of 80°C ± 2°C respectively, to measure how the
120 keep-power varies with time.
100
) MAX Room
MIN temperature
80
) MAX High
MIN temperature
60
40
20
0
50 100
500 1,000 5,000 10,000
Elapsed time (H)
8