G2R-14-DC5 Datasheet, PDF (6/14 Pages) Omron Electronics LLC – 1General purpose power Relays of single-pole10 A and double-pole 5 A.
G2R
PCB Power Relay
■Characteristics
● Standard Relays
Item
Number of poles
1-pole
2-pole
Contact resistance *1
30 mΩ max.
50 mΩ max.
Operate time *2
15 ms max.
Release time *2
AC: 10 ms max.; DC: 5 ms max.
Max.
Mechanical
18,000 operations/hr
operating
frequency
Electrical
1,800 operations/hr
Insulation resistance *3
1,000 MΩ min.
Between coil and
contacts
5,000 VAC, 50/60 Hz for 1 min
Dielectric
strength
Between contacts
of different polarity
-
3,000 VAC, 50/60 Hz
for 1 min
Between contacts
of the same
1,000 VAC, 50/60 Hz for 1 min
polarity
Vibration Destruction
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
resistance
Malfunction
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
Shock
Destruction
resistance Malfunction
1,000 m/s2
200 m/s2 when energized;
100m/s2 when no energized
AC coil: 10,000,000 operations min.;
Mechanical
DC coil: 20,000,000 operations min.
Durability
(at 18,000 operations/hr)
G
Electrical
100,000 operations min.
(at 1,800 operations/hr under rated load)
2 Ambient operating temperature
-40°C to 70°C (with no icing)
R Ambient operating humidity
5% to 85%
Weight
Approx. 17 g (Approx. 20 g *4)
Note: The values here are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
*3. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
*4. Value for quick-connect terminals.
■Engineering Data
Double-winding Latching Relays
Item
Number of poles
1-pole
2-pole
Contact resistance *1
30 mΩ max.
50 mΩ max.
Set
Time *2
Min. set pulse width
20 ms max.
30 ms
Time *2
20 ms max.
Reset
Min. reset pulse
width
30 ms
Max. operating Mechanical
18,000 operations/hr
frequency
Electrical
1,800 operations/hr
Insulation resistance *3
1,000 MΩ min. (at 500 VDC)
Between coil and
contacts
5,000 VAC, 50/60 Hz for 1 min
Dielectric
strength
Between contacts
of different polarity
Between contacts
of the same
−
3,000 VAC,
50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min
polarity
Between set and
reset coils
1,000 VAC, 50/60 Hz for 1 min
Vibration
Destruction
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
resistance
Malfunction
10 to 55 to 10 Hz, 0.75 mm single
amplitude (1.5 mm double amplitude)
Shock
resistance
Destruction
Malfunction
1,000 m/s2
Set: 500m/s2 Armature OFF
Reset: 200m/s2 Contact OFF
Durability
Mechanical
Electrical
10,000,000 operations min
(at 18,000 operations/hr)
100,000 operations min. (at 1,800
operations/hr under rated load)
Ambient operating temperature
-40°C to 70°C (with no icing or
condensation)
Ambient operating humidity
5% to 85%
Weight
Approx. 17 g
Note: The values here are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage-drop method.
*2. Measurement conditions: Rated operating voltage applied, not including
contact bounce.
*3. Measurement conditions: The insulation resistance was measured with a
500 VDC megohmmeter at the same locations as the dielectric strength
was measured.
● Maximum Switching Capacity
Flux Protection/Plug-in Relays
G2R-1, G2R-1A, G2R-1-T, G2R-1A-T
50
AC resistive load
10
5
AC
DC resistive load
inductive load
(cosφ = 0.4)
1
DC inductive load
(L/R = 7 ms)
0.5
G2R-1-E, G2R-1A-E
50
AC resistive load
16
10
5
DC resistive load
AC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
1
0.5
G2R-1Z, G2R-1AZ
50
10
AC resistive load
5
AC
inductive load
DC resistive load
(cosφ = 0.4)
1
0.5
DC inductive load
(L/R = 7 ms)
0.1
0
5 10 20 30 50 100
500
Switching voltage (V)
G2R-1-H, G2R-1A-H, G2R-2, G2R-2A
50
0.1
0
5 10 20 30 50 100
500
Switching voltage (V)
G2R-2-H, G2R-2A-H
50
0.1
0
5 10 20 30 50 100
500
Switching voltage (V)
10
AC resistive load
5
AC
DC resistive load
inductive load
1
(cosφ = 0.4)
DC inductive load
0.5
(L/R = 7 ms)
0.1
0
6
5 10 20 30 50 100
500
Switching voltage (V)
10
5
AC resistive load
1
0.5
0.1
0
DC resistive load
AC
inductive load
(cosφ = 0.4)
DC inductive load
(L/R = 7 ms)
5 10 20 30 50 100
500
Switching voltage (V)