SPECIFICATIONS
LASER
SENSORS
GX-8 type
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
Type
Front sensing
Item
Top sensing
Max. operation distance (Note 3)
GX-F8A(I)
GX-H8A(I)
NPN output
PNP output
GX-F8B(I)
GX-F8A(I)-P
GX-F8B(I)-P
GX-H8B(I)
GX-H8A(I)-P
GX-H8B(I)-P
2.5 mm 0.098 in ± 8 %
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Stable sensing range (Note 3)
Standard sensing object
Hysteresis
Repeatability
Supply voltage
Current consumption
0 to 2.1 mm 0 to 0.083 in
Iron sheet 15 × 15 × t 1 mm 0.591 × 0.591 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less
12
to
24
V
DC
+10
–15
%  Ripple
P-P
10
%
or
less
15 mA or less
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Output
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 100 mA
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V) • Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (at 100 mA sink current)
• Residual voltage: 2 V or less (at 100 mA source current)
WIRE-SAVING
SYSTEMS
Utilization category
DC-12 or DC-13
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
Output operation
Max. response frequency
Operation indicator
Pollution degree
Protection
Ambient temperature
Normally open
Normally closed
Normally open
500 Hz
Orange LED (lights up when the output is ON)
3 (Industrial environment)
IP68 (IEC), IP68g (JEM) (Note 4, 5)
–25 to +70 °C –13 to +158 °F, Storage: – 40 to +85 °C – 40 to +185 °F
Normally closed
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Ambient humidity
EMC
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Sensing
range
variation
Temperature characteristics
Voltage characteristics
Material
Cable
35 to 85 % RH, Storage: 35 to 95 % RH
EN 60947-5-2
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in amplitude (Max. 20 G) in X, Y and Z directions for two hours each
10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ± 8 % of sensing range at +23 °C +73 °F
Within
±2
%
for
+10
–15
%
fluctuation
of
the
supply
voltage
Enclosure: PBT, Indicator part: Polyester
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long
Cable extension
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Selection
Guide
Amplifier
Built-in
Amplifier-
separated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
Net weight
Front sensing type: 15 g approx., Top sensing type: 20 g approx..
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73 °F.
2) “ I ” in the model No. indicates a different frequency type.
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
4) Panasonic Electric Works SUNX’s IP68 test method
1 Immerse at 0 m below 0 °C +32 °F water surface and leave for 30 min. Then, immerse at 0 m below +70 °C +158 °F water surface and leave for 30 min.
2 Regard the heat shock test in 1 as one cycle and perform 20 cycles.
3 Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.
4 After tests 1 to 3 , insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values.
5) If using the sensor in an environment where cutting oil droplets splatter, the sensor may deteriorate due to added substances in the oil.