English
Language : 

GX-F8A Datasheet, PDF (6/16 Pages) Omron Electronics LLC – Rectangular-shaped Inductive Proximity Sensor
GX-F/H Rectangular-shaped Inductive Proximity Sensor
SERIES
766
SPECIFICATIONS
FIBER
SENSORS
GX-6 type
Type
Front sensing
Item
Top sensing
Max. operation distance (Note 3)
Stable sensing range (Note 3)
Standard sensing object
Hysteresis
Repeatability
Supply voltage
Current consumption
GX-F6A(I)
GX-H6A(I)
NPN output
PNP output
GX-F6B(I)
GX-F6A(I)-P
GX-F6B(I)-P
GX-H6B(I)
GX-H6A(I)-P
GX-H6B(I)-P
1.6 mm 0.063 in ± 8 %
0 to 1.3 mm 0 to 0.051 in
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
20 % or less of operation distance (with standard sensing object)
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less
12
to
24
V
DC
+10
–15
%  Ripple
P-P
10
%
or
less
15 mA or less
Output
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 100 mA
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between output and 0 V) • Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (at 100 mA sink current)
• Residual voltage: 2 V or less (at 100 mA source current)
Utilization category
DC-12 or DC-13
Output operation
Normally closed
Normally closed
Normally closed
Normally closed
Max. response frequency
400 Hz
Operation indicator
Orange LED (lights up when the output is ON)
Pollution degree
3 (Industrial environment)
Protection
IP68 (IEC), IP68g (JEM) (Note 4, 5)
Ambient temperature
–25 to +70 °C –13 to +158 °F, Storage: – 40 to +85 °C – 40 to +185 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 95 % RH
EMC
EN 60947-5-2
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 500 Hz frequency, 3 mm 0.118 in amplitude (Max. 20 G) in X, Y and Z directions for two hours each
Shock resistance
10,000 m/s2 acceleration (1,000 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Material
Temperature characteristics
Voltage characteristics
Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ± 8 % of sensing range at +23 °C +73 °F
Within
±2
%
for
+10
–15
%
fluctuation
of
the
supply
voltage
Enclosure: PBT, Indicator part: Polyester
Cable
0.15 mm2 3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long
Cable extension
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight
15 g approx.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73 °F.
2) “ I ” in the model No. indicates a different frequency type.
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
4) Panasonic Electric Works SUNX’s IP68 test method
1 Immerse at 0 m below 0 °C +32 °F water surface and leave for 30 min. Then, immerse at 0 m below +70 °C +158 °F water surface and leave for 30 min.
2 Regard the heat shock test in 1 as one cycle and perform 20 cycles.
3 Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.
4 After tests 1 to 3 , insulation resistance, voltage withstandability, current consumption, and sensing range must meet the standard values.
5) If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Amplifier
Built-in
Amplifier-
separated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX