English
Language : 

E3S-C Datasheet, PDF (6/10 Pages) Omron Electronics LLC – Oil-resistive, long-distance photoelectric sensor (metal case)
Characteristic data (typical)
Operating Range
Through-beam
E3S-CT#1(-M1J)
500
300
100
50
30
Retroreflective Models
E3S-CR#1 (-M1J) + E39-R1 (supplied reflector)
500 Reflector: E39-R1
300
Diffuse-reflective
E3S-CD##(-M1J)
500 Sensing object: White paper
300
E3S-CD#1
100
100
50
50
30
30
E3S-CD#2
10
10
10
5
5
5
3
3
3
Operation
level
1
0
10
20
30
40
Operation
level
1
0
1
2
3
4
Operation
level
1
0
1
2
3
Distance (m)
Distance (m)
Distance (m)
Nomenclature:
(Horizontal type)
Control unit cover
(Vertical type)
Control unit cover
Stability
indicator (green)
NPN and PNP
output selector * 1
S
L
Min
Max
SENS
PNP D·ON
NPN L·ON
E3S-CD12
Light indicator (red)
Sensitivity adjuster
L-ON and D-ON
selector * 2
Model
Stability indicator
(green)
NPN and PNP
output selector * 1
S
D
L SENS
PNP ON
NPN L
Min
Max
ON
Light indicator
(red)
Sensitivity adjuster
L-ON and
D-ON selector * 2
*1. The output transistor can be selected with the NPN/PNP output selector.
*2. The operation mode can be selected with the L/OND/ON selector.
Note: The through-beam and retroreflective models are different in sensitivity
adjuster shape.
Operation
Sensitivity adjustment (diffuse reflective model, light-ON)
Sequence Detection state Sensitivity adjuster Indicator state
Adjustment procedure
A Point A
Photoelectric
Sensor
B Point B
Photoelectric Sensor
C Setting
---
ONÆOFF OFFÆON Place a sensing object in the predetermined position, turn the
sensitivity adjuster clockwise (increase sensitivity) until the
incident indicator (red) is turned ON, and define this position
Stability indicator Light indicator as (A).
(green)
(red)
Remove the sensing object, turn the sensitivity adjuster fur-
ther clockwise until the incident indicator (red) is turned ON
ONÆOFF ONÆOFF
by a background object, and define this position as (B). Turn
the sensitivity adjuster counterclockwise (decrease sensitivi-
Stability indicator Light indicator ty) from (B) until the incident indicator (red) is turned OFF,
(green)
(red) and define this position as (C). When there is no background
object, define the maximum adjuster position (Max) as (C).
Set the adjuster in the middle of positions (A) and (C) (opti-
ON
ON´OFF mum sensitivity setting). Also make sure that the stability in-
dicator (green) is turned ON when there is an object and
when there is no object.
Stability indicator Light indicator When the indicator is not turned ON, recheck the detection
(green)
(red) method since there is a little allowance.
Unlike the conventional models, the E3S-C scarcely has sensitivity variations between products. Therefore, you need to make the
above adjustment on only one diffuse reflective model of E3S-CD that will be used for detection under the same conditions, and
match the indicator points of the other diffuse reflective models of E3S-CD with the above adjusted one. (You need not match the
sensitivity of each sensor.)
E3S-C