G2R-1A Datasheet, PDF (5/19 Pages) Omron Electronics LLC – PCB Relay A Power Relay for a Variety of Purposes with Various Models
G2R
G2R
PCB/Fully sealed Relays
Item
General-purpose (single contact)
Bifurcated contact
Number of poles
1 pole
2 poles
1 pole
Load
Resistive load
(cosf = 1)
Inductive load
(cosf = 0.4;
L/R = 7 ms)
Resistive load
(cosf = 1)
Inductive load
(cosf = 0.4;
L/R = 7 ms)
Resistive load
(cosf = 1)
Inductive load
(cosf = 0.4;
L/R = 7 ms)
Rated load
8 A at 250 VAC; 6 A at 250 VAC; 4 A at 250 VAC; 1.5 A at 250 VAC; 5 A at 250 VAC; 2 A at 250 VAC;
8 A at 30 VDC 4 A at 30 VDC 4 A at 30 VDC 2.5 A at 30 VDC 5 A at 30 VDC 3 A at 30 VDC
Rated carry current 8 A
4A
5A
Max. switching voltage 380 VAC, 125 VDC
380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current 8 A
4A
5A
Max. switching power 2,000 VA,
240 W
1,500 VA,
120 W
1,000 VA,
120 W
375 VA,
75 W
1,250 VA,
150 W
500 VA,
90 W
Failure rate
(reference value)
100 mA at 5 VDC
10 mA at 5 VDC
1 mA at 5 VDC
Note: P level: l60 = 0.1 x 10–6/operation
Latching Relays
Number of poles
Load
1 pole
Resistive load
(cosf = 1)
Rated load
5 A at 250 VAC;
5 A at 30 VDC
Rated carry current 5 A
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 5 A
Max. switching power 1,250 VA, 150 W
Failure rate
(reference value)
100 mA at 5 VDC
Note: P level: l60 = 0.1 x 10-6/operation
I Characteristics
Standard Relays
Inductive load
(cosf = 0.4;
L/R = 7 ms)
3.5 A at 250 VAC;
2.5 A at 30 VDC
875 VA, 75 W
2 poles
Resistive load
(cosf = 1)
3 A at 250 VAC;
3 A at 30 VDC
3A
380 VAC, 125 VDC
3A
750 VA, 90 W
10 mA at 5 VDC
Inductive load
(cosf = 0.4;
L/R = 7 ms)
1.5 A at 250 VAC;
2 A at 30 VDC
375 VA, 60 W
Item
Contact resistance
Operate (set) time
Release (reset) time
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
1 pole
2 poles
30 mW max. (high-capacity type: 100 mW max.) 50 mW max.
15 ms max.
AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.)
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 MW min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts
of same polarity
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100m/s2 when no energized
Mechanical: AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr under rated load)
Operating: -40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g (plug-in terminal: approx. 20 g)
Note: Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.