English
Language : 

G2R-1A Datasheet, PDF (4/19 Pages) Omron Electronics LLC – PCB Relay A Power Relay for a Variety of Purposes with Various Models
G2R
G2R
Double-winding Latching Relays
Rated voltage
Set coil
Rated current (see note 1.)
Coil resistance (see note 1.)
Coil inductance Armature OFF
(H) (ref. value)
Armature ON
Reset coil
Rated current
Coil resistance
Coil inductance Armature OFF
(H) (ref. value)
Armature ON
Must set voltage
Must reset voltage
Max. voltage
Power consumption
5 VDC
6 VDC
12 VDC
167 mA
138 mA
70.6 mA
30 W
43.5 W
170 W
0.073
0.104
0.42
0.146
0.208
0.83
119 mA
100 mA
50 mA
42 W
60 W
240 W
0.003
0.005
0.018
0.006
0.009
0.036
70% max. of rated voltage
70% max. of rated voltage
140% of rated voltage (at 23•C)
Set coil: Approx. 850 mW; Reset coil: Approx. 600 mW
24 VDC
34.6 mA
694 W
1.74
3.43
25 mA
960 W
0.079
0.148
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
I Contact Ratings
PCB/Flux Protection, Plug-in, Quick-connect Terminal Relays
Item
General-purpose, quick-connect terminal
Number of poles
1 pole
2 poles
Load
Resistive load
(cosf = 1)
Inductive load
(cosf = 0.4;
L/R = 7 ms)
Resistive load Inductive load
(cosf = 1)
(cosf = 0.4;
L/R = 7 ms)
Rated load
10 (1) A at 250 VAC; 7.5 A at 250
10 (1) A at 30 VDC VAC;
5 A at 30 VDC
5 A at 250
2 A at 250 VAC;
VAC;
3 A at 30 VDC
5 A at 30 VDC
Rated carry current 10 (1) A
5A
Max. switching voltage 380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current 10 (1) A
5A
Max. switching power 2,500 (250) VA,
300 (30) W
1,875 VA,
150 W
1,250 VA,
150 W
500 VA,
90 W
Failure rate
(reference value)
100 mA at 5 VDC (1 mA at 5 VDC)
10 mA at 5 VDC
High-capacity
1 pole
Resistive load Inductive load
(cosf = 1)
(cosf = 0.4;
L/R = 7 ms)
16 A at 250
8 A at 250 VAC;
VAC;
8 A at 30 VDC
16 A at 30 VDC
16 A
380 VAC, 125 VDC
16 A
4,000 VA,
480 W
2,000 VA,
240 W
100 mA at 5 VDC
Note: 1. P level: l60 = 0.1 x 10–6/operation
2. ( ): Bifurcated crossbar contact type.
PCB/Flux Protection Relays
Item
Bifurcated contacts
Number of poles
1 pole
Load
Resistive load
(cosf = 1)
Inductive load
(cosf = 0.4;
L/R = 7 ms)
Rated load
5 A at 250 VAC; 2 A at 250 VAC;
5 A at 30 VDC 3 A at 30 VDC
Rated carry current 5 A
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 5 A
Max. switching power 1,250 VA,
150 W
500 VA,
90 W
Failure rate
(reference value)
1 mA at 5 VDC
Note: P level: l60 = 0.1 x 10–6/operation
High-sensitivity
1 pole
2 poles
Resistive load
(cosf = 1)
Inductive load
(cosf = 0.4;
L/R = 7 ms)
Resistive load
(cosf = 1)
Inductive load
(cosf = 0.4;
L/R = 7 ms)
5 A at 250 VAC; 2 A at 250 VAC; 3 A at 250 VAC; 1 A at 250 VAC;
5 A at 30 VDC 3 A at 30 VDC 3 A at 30 VDC 1.5 A at 30 VDC
5A
3A
380 VAC, 125 VDC
380 VAC, 125 VDC
5A
3A
1,250 VA,
150 W
500 VA,
90 W
750 VA,
90 W
250 VA,
45 W
100 mA at 5 VDC
10 mA at 5 VDC
144