English
Language : 

EESX670 Datasheet, PDF (4/13 Pages) Omron Electronics LLC – Photomicrosensor with 50- to 100-mA direct switching capacity for built-in application.
Engineering Data (Typical)
Sensing Position Characteristics
Sensing Position Characteristics
Tr ON
Dark-ON
Tr ON
Dark-ON
EE-SX47/67
Repeated Sensing Position Characteristics
d
OFF
∆d2
∆d3
∆d1
∆d4
d
∆d5
d
ON
Ta = −25°C Ta = 55°C Ta = 25°C
Tr OFF
0
Tr OFF
1.0
2.0
3.0
4.0 5.0 6.0
0
Distance d (mm)
1.0
2.0 3.0
4.0 5.0 6.0
0
3.00
3.02
3.04
3.06 3.08
Distance d (mm)
Distance d (mm)
Vcc =12 V, No. of repetitions: 20, ∆d1 = 0.002 mm,
∆d2 = 0.004 mm, ∆d3 = 0.005 mm, ∆d4 = 0.02 mm,
∆d5 = 0.04 mm
Note: The data applies to dark status. Operation may
be affected by external light interference or light
coming through the sensing object.
I/O Circuit Diagrams
NPN Output
Model
Output
configuration
Timing charts
EE-SX67@
EE-SX67@-WR
EE-SX67@-CJ1-R
Light-ON
Dark-ON
Incident
Interrupted
Light indicator ON
(red)
OFF
Output
transistor
ON
OFF
Load 1 Operates
(e.g., relay) Releases
H
Load 2
L
Incident
Interrupted
Light indicator ON
(red)
OFF
Output
transistor
ON
OFF
Load 1 Operates
(e.g., relay) Releases
H
Load 2
L
EE-SX670A
EE-SX671A
EE-SX672A
EE-SX673A
EE-SX674A
Light-ON
Dark-ON
Incident
Interrupted
Light indicator ON
(red)
OFF
Output
transistor
ON
OFF
Load 1 Operates
(e.g., relay) Releases
H
Load 2
L
Incident
Interrupted
Light indicator ON
(red)
OFF
Output
transistor
ON
OFF
Load 1 Operates
(e.g., relay) Releases
Load 2
H
L
Incident
EE-SX470
EE-SX471
EE-SX472
EE-SX473
EE-SX474
Light-ON
Interrupted
Light indicator ON
(red)
OFF
Output
transistor
ON
OFF
Load 1
(relay)
Operates
Releases
H
Load 2
L
*1. Do not connect the L terminal to 0 V when using dark-ON operation.
Terminal
connections
Short-circuited
between
L terminal and
positive terminal
Output circuit
Open between
L terminal and
positive terminal
*1
Light indicator
(red)
Main
circuit
*
L
Load
OUT
IC (Control output)
100 mA max.
5 to
24 VDC
Short-circuited
between
L terminal and
positive terminal
*The terminal arrangement depends on the model.
Check the dimensional diagrams.
Open between
L terminal and
positive terminal
*1
Light indicator
(red)
---
Main
circuit
OUT
IC
Load
5 to
24 VDC
4