English
Language : 

S8PE Datasheet, PDF (3/8 Pages) Omron Electronics LLC – Three phase input switch mode Power Supply (DIN-rail mounting, 3-phase input Switch mode Power Supply with a range of 5A to 40A output current)
Engineering Data
I Definition of Inrush Current, Start up Time and Hold Time
Input ON
AC input
voltage
Input OFF
AC input
current
Inrush current input application
90%
96.5%
Output
voltage
Start up time
I Overload Protction
The Power supply is provided with an overload protec tion function
that protect the load and the power sup ply from possible damage by
over current. When the output current rises above between 105 to
130% of the rated current, the protection function is triggered,
decreasing the output voltage. When output current falls within the
rated range, the overload protection function is automatically cleared.
I De-rating Curve
Hold time
I Overvoltage Protction
(except for 40 A model)
If output voltage exceed the rated voltage more than 20% (50% at
maximum) by some reason, then the output voltage will be turned
OFF automatically for safety. To restart the S8PE, turn OFF the input
voltage, wait for about one minute, then apply the input power again.
Ambient temperature (°C)
For UL and CSA the maximum temperature is 50% (with derating of
2%/°C from 40 °C to 50 °C, only for 40 A model)
Three phase input switch mode Power Supply S8PE L-101