Specifications
■ Input Ratings
(Ambient temperature: 25°C [77°F])
Type
Rated
voltage
G3NA-2❏❏B
G3NA-4❏❏B
G3NA-D210B
G3NA-275B-UTU-2
G3NA-290B-UTU-2
G3NA-475B-UTU-2
G3NA-490B-UTU-2
5 to 24 VDC
100 to 120 VAC
200 to 240 VAC
5 to 24 VDC
100 to 240 VAC
5 to 24 VDC
100 to 240 VAC
Operating
voltage range
4 to 32 VDC
75 to 132 VAC
150 to 264 VAC
4 to 32 VDC
75 to 264 VAC
4 to 32 VDC
75 to 264 VAC
Impedance
(See note 1)
7 mA max. (see note 2)
36 kΩ ±20% (see note 4)
72 kΩ ±20%
5 mA max. (see note 2)
72 kΩ ±20%
15 mA max. (see note 6)
Voltage level
Must operate voltage Must release voltage
4 VDC max.
1 VDC min.
75 VAC max. (see note 3) 20 VAC min. (see note 3)
150 VAC max. (see note 3) 40 VAC min. (see notes 3 and 5)
4 VDC max.
1 VDC min.
75 VAC max.
20 VAC min.
4 VDC max.
1 VDC min.
72 kΩ ±20%
75 VAC max.
20 VAC min.
Note: 1. The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC,
the input impedance is measured at 120 VAC).
2. With constant current input circuit system, the impedance for the G3NA-2❏❏B-UTU is 15mA max.
3. Refer to the “Characteristic Data” for further details.
4. The G3NA-240B(-UTU) is 72kΩ ±20%
5. The G3NA-240B(-UTU) is 20 VAC min.
6. The impediance for G3NA-475B-UTU-2 and G3NA-490B-UTU-2 is 7 mA max.
■ Output Ratings
Type
Applicable load
Rated
Load
load voltage voltage range
Load current
With heat sink* Without heat sink
Surge current
VDRM, VCEO
(Ref. Value)
G3NA-205B
G3NA-210B
G3NA-410B
G3NA-220B
G3NA-420B
G3NA-240B
G3NA-440B-2
G3NA-450B
24 to 240 VAC
24 to 240 VAC
200 to 480 VAC
24 to 240 VAC
200 to 480 VAC
24 to 240 VAC
200 to 480 VAC
200 to 480 VAC
19 to 264 VAC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
180 to 528 VAC
0.1 to 5 A (at 40°C)
0.1 to 10 A (at 40°C)
0.2 to 10 A (at 40°C)
0.1 to 20 A (at 40°C)
0.2 to 20 A (at 40°C)
0.1 to 40 A (at 40°C)
0.2 to 40 A (at 40°C)
0.2 to 50 A (at 40°C)
0.1 to 3 A (at 40°C)
0.1 to 4 A (at 40°C)
0.2 to 4 A (at 40°C)
0.1 to 4 A (at 40°C)
0.2 to 4 A (at 40°C)
0.1 to 6 A (at 40°C)
0.2 to 6 A (at 40°C)
0.2 to 6 A (at 40°C)
60 A (60 Hz, 1 cycle)
150 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle)
440 A (60 Hz, 1 cycle)
600V (VDRM)
600V (VDRM)
1,200V (VDRM)
600V (VDRM)
1,200V (VDRM)
600V (VDRM)
1,200V (VDRM)
G3NA-D210B
5 to 200 VDC
G3NA-275B-UTU-2 24 to 240 VAC
G3NA-475B-UTU-2 200 to 480 VAC
G3NA-290B-UTU-2 24 to 240 VAC
G3NA-490B-UTU-2 200 to 480 VAC
4 to 220 VDC
19 to 264 VAC
180 to 528 VAC
19 to 264 VAC
180 to 528 VAC
0.1 to 10 A (at 40°C)
1 to 75 A (at 40°C)
1 to 75 A (at 40°C)
1 to 90 A (at 40°C)
1 to 90 A (at 40°C)
0.1 to 4 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
1 to 7 A (at 40°C)
20 A (10 ms)
400V (VCEO)
800 A (60 Hz, 1 cycle) 600V (VDRM)
800 A (60 Hz, 1 cycle) 1,200V (VDRM)
1,000 A (60 Hz, 1 cycle) 600V (VDRM)
1,000 A (60 Hz, 1 cycle) 1,200V (VDRM)
*When the appropriate size OMRON heat sink is used.
Note: The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature charts in the Engineering
Data section.