G2RS Datasheet, PDF (3/12 Pages) List of Unclassifed Manufacturers – General-purpose Relay
■ Contact Ratings
Number of poles
Load
Resistive load
(cosφ = 1)
Rated load
10 A at 250 VAC;
10 A at 30 VDC
Rated carry current
10 A
Max. switching voltage
440 VAC, 125 VDC
Max. switching current
10 A
Max. switching capacity
2,500 VA,
300 W
Minimum permissible load
100 mA at 5 VDC
Note: P level: λ60 = 0.1 x 10-6/operation
■ Characteristics
1 pole
Inductive load
(cosφ = 0.4; L/R = 7 ms)
7.5 A at 250 VAC;
5 A at 30 VDC
1,875 VA,
150 W
Resistive load
(cosφ = 1)
5 A at 250 VAC;
5 A at 30 VDC
5A
380 VAC, 125 VDC
5A
1,250 VA,
150 W
10 mA at 5 VDC
2 poles
Inductive load
(cosφ = 0.4; L/R = 7 ms)
2 A at 250 VAC; 3 A at
30 VDC
500 VA,
90 W
Item
1 pole
2 poles
Contact resistance 100 mΩ max.
Operate (set) time
15 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max.
(w/built-in diode: 20 ms max.)
AC: 15 ms max.; DC: 10 ms max.
(w/built-in diode: 20 ms max.)
Max. operating
frequency
Mechanical:
Electrical:
18,000 operations/hr
1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength
5,000 VAC, 50/60 Hz for 1 min between coil and 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
same polarity
Vibration resistance Destruction:
Malfunction:
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock resistance
Destruction:
Malfunction:
1,000 m/s2
200 m/s2 when energized; 100 m/s2 when not energized
Service life
Mechanical:
Electrical:
AC coil: 10,000,000 operations min.;
DC coil: 20,000,000 operations min. (at 18,000 operations/hr)
100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type)
Ambient temperature Operating:
–40°C to 70°C (with no icing or condensation)
Ambient humidity
Operating:
5% to 85%
Weight
Approx. 21 g
Note: Values in the above table are the initial values.
*4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is used.
■ Approved Standards
UL Recognized (File No. E41643) - - Ambient Temp. = 40°C
IEC/VDE (EN61810)
Model Contact Coil ratings
form
Contact ratings
Cycles
G2R-1-S SPDT
G2R-2-S DPDT
5 to 110 VDC
5 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
6 x 103
Contact Coil ratings
form
1 pole
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
2 poles
6, 12, 24, 48 VDC
24, 110, 120, 230,
240 VAC
Contact ratings
5 A, 440 VAC (cosφ = 1.0)
10 A, 250 VAC (cosφ = 1.0)
10 A, 30 VDC (0 ms)
5 A, 250 VAC (cosφ =1.0)
5 A, 30 VDC (0 ms)
Cycles
100 x 103
100 x 103
CSA Certified (File No. LR31928)
LR
Model Contact Coil ratings
form
Contact ratings
Cycles
G2R-1-S SPDT
G2R-2-S DPDT
5 to 110 VDC
5 to 240 VAC
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
6 x 103
6 x 103
Number Coil ratings
of poles
Contact ratings
1 pole
5 to 110 VDC
5 to 240 VDC
10 A, 250 VAC (general use)
7.5 A, 250 VAC (PF0.4)
10 A, 30 VDC (resistive)
5A, 30VDC (L/R=7ms)
2 poles
5 to 110 VDC
5 to 240 VDC
5 A, 250 VAC (general use)
2 A, 250 VAC (PF0.4)
5 A, 30 VDC (resistive)
3A, 30VDC (L/R=7ms)
Cycles
100 x 103
100 x 103
General-purpose Relay G2RS-(S) 247