English
Language : 

H2C Datasheet, PDF (2/8 Pages) Omron Electronics LLC – Motor Timer
H2C
Specifications
Time Ranges
Five time ranges are available for each timer by turning the time range selector every 60 degrees.
Note: Rated time is displayed on the window.
Time range code
Position of time range selector
H2C
A
1.25 to 30 s
7.5 s to 3 min
1.25 to 30 min
7.5 min to 3 hrs
1.25 to 30 hrs
B
0.2 to 6 s
2 to 60 s
0.2 to 6 min
2 to 60 min
0.2 to 6 hrs
C
0.5 to 12 s
5 to 120 s
0.5 to 12 min
5 to 120 min
0.5 to 12 hrs
Ratings
Item
H2C
Rated supply voltage
100, 110, 115, 120, 200, 220, or 240 VAC (50/60 Hz) (see note 1)
Operating voltage range
85% to 110% of rated supply voltage (see note 2)
Power consumption
Approx. 3.5 VA
Control outputs
6 A at 250 VAC, resistive load (cos! = 1) (see note 3)
Note:
1. The front panel of the timer is color coded to identify the following supply voltage classifications:
100 to 120 V: Blue
200 to 240 V: Red
Other classes: Black
2. If the voltage continues to be applied after the set time has elapsed, the operating voltage range will change to between 90% and
110% of the rated voltage.
3. The switching capacity of the control output is 6 A at 250 VAC (cos" = 1). Refer to “Engineering Data” since the electrical service life
of the built-in switch will change in such a case.
Characteristics
Accuracy of operating time
Setting error
Reset time
Influence of voltage
Influence of temperature
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
Motor life expectancy
Approved standards
Weight
#0.5% max. $#1% max. at 0.2 to 6 s for the time range code B or at 0.5 to 12 s for the time
range code C)
#2% max.
0.5 s max.
#1% max.
#2% max.
100 M% min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts)
2,000 VAC, 50/60 Hz for 1 min (between contact and control circuit and between contacts of
different polarities)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Destruction: 10 to 55 Hz with 0.75-mm double amplitude
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 150 m/s2 (approx. 15G)
Operating: --10&C to 50&C
Storage: --25&C to 65&C
Operating: 45% to 85%
Mechanical: 10,000,000 operations min.
500,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h)
Electrical: See “Engineering Data”
20,000 hrs
UL (File No. E52800)
H2C series: approx. 180 g
H2C-F series: approx. 270 g
2