English
Language : 

G2A-434A-NAC115 Datasheet, PDF (2/10 Pages) Omron Electronics LLC – Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control
■ Relays Other than Standard Models
Arc barrier equipped
Built-in diode
Built-in operation indicator
G2A-432AY
G2A-432A-D
G2A-432A-N
The arc barrier equipped model is The built-in diode model is a relay The built-in operation indicator
a relay designed to prevent arc which incorporates a diode for ab- model has a newly added opera-
short-circuiting between phases sorption of the reverse voltage tion indicator to the conventional
and can be used in a circuit which that may be generated when the operation indication mechanism
has potential difference between coil is de-energized. Because the and facilitates operation monitor-
phases. The switching power of release time of this model is long- ing without being affected by am-
such a circuit with potential differ- er than the standard model, pay bient illumination.
ence must be limited to less than adequate attention to this point in With the -N model (rated at 16,
1/2 the rated load when using this designing a circuit. Also, pay at- 12, 24, and 48 VDC) and -N1
Relay.
tention to the + polarity of the coil. model rated at 6, 12, 24, 48, and
The reverse-breakdown voltage 100 VDC), pay attention to the +
of the diode is 1,000 V.
polarity of the coil.
■ Accessories
G2A
Sockets
Track mounting Front-connecting
Screw terminals
Socket
PYF14A
PYF14(-E), PYF14A-
TU, PYF14T
Solder terminals
Wire-wrap terminals
Without Hold- With Hold-down Without Hold- With Hold-down
down Clip
Clip
down Clip
Clip
PCB
terminals
PY14, PY14-3
(see note)
PY14-Y2
PY14QN(2)
PY14QN(2)-Y2
PY14-0,
PY14-02
Note: With monitor terminal.
Relay Hold-down Clips
Socket Mounting Plates
For Front-connecting Socket
For Back-connecting Socket
For Socket Mounting Plate
PYC-A2
PYC-3/PYC-5
PYC-2
For one Socket
For 18 Sockets
For 36 Sockets
PYP-1
PYP-18
PYP-38
Specifications
■ Coil Ratings
The rated currents for some of the built-in operation indicator models differ from the values given in this table. Refer to note 5 below.
Rated
voltage
Rated current
50 Hz
60 Hz
6 VAC
12 VAC
24 VAC
50 VAC
100/
110 VAC
200/
220 VAC
6 VDC
12 VDC
24 VDC
48 VDC
100 VDC
295 mA
148 mA
73 mA
35 mA
17.7/
21.4 mA
8.9/
10.8 mA
176 mA
88 mA
45 mA
22 mA
11.4 mA
233 mA
117 mA
58 mA
28 mA
14/
16.8 mA
7/8.4 mA
Coil
resistance
8.9 Ω
34 Ω
136 Ω
530 Ω
2,200 Ω
8,800 Ω
34 Ω
136 Ω
530 Ω
2,200 Ω
8,800 Ω
Coil inductance (ref.
value)
Armature Armature
OFF
ON
0.048 H
0.065 H
0.166 H
0.257 H
0.691 H
1.04 H
3.08 H
4.53 H
12.42/
12.38 H
18/16.4 H
42.2/
41.8 H
72/65.5 H
0.14 H
0.26 H
0.6 H
1.0 H
2.7 H
4.6 H
11 H
19 H
43 H
73 H
Must
operate
Must
release
Max.
voltage
% of rated voltage
80 % max. 30 % min. 110 %
10 % min. 110 %
Power
consumption
Approx. 1.4 VA
Approx. 1.1 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for AC rated current and
±15% for DC coil resistance.
2. The AC coil resistance and coil inductance values are for reference only.
3. Performance characteristic data is measured at a coil temperature of 23°C.
4. The maximum voltage is one that is applicable instantaneously to the Relay coil at an ambient temperature of 23°C and not continuously.
5. For built-in operation indicator models rated at 6, 12, and 24 VDC, add an LED current of approx. 5 mA to the rated currents.
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
2