Precautions
Install the Sensor in a clean environment keep the filter (on the
front of the Sensor) free from oil and dust. If affected by oil or
dust, clean the Sensor as follows:
1. Use a blower brush (used to clean camera lenses) to blow
large dust particles from the surface. Do not blow the dust
away with your mouth.
2. Use a soft cloth (for lenses) with a little alcohol to remove
the remaining dust.
Do not use a scrubbing action when cleaning as a scratch
on the filter could result in the Sensor malfunctioning.
Interference
Z4W-V25R LED Displacement Sensors can be installed within
close proximity to each other and operate independently without
interference (refer to the figures below). However, if they are
installed at an oblique angle to each other, interference may
result.
Environment
Refrain from using the LED Displacement Sensor in a strong
electromagnetic field or in an environment where the operation of
the Sensor is subject to the reflection of intensive light (such as a
laser beam or an electric arc welding machine).
The LED Displacement Sensor cannot accurately detect a mirror-
like object, a transparent object, one with an extremely small
reflection ratio, an object smaller than the diameter of the Sen-
sor’s sensing spot, or an inclined object.
Wiring
The power supply cable for the Z4W-V25R should not be wired
with high-voltage lines or power lines in order to avoid interfer-
ence, damage, or malfunction.
Others
The Sensor cannot detect an object accurately if the surface of
the object consists of different materials placed next to each other
(refer to the figures below). In such case install the Sensor so that
the boundaries of the materials and the Sensor are parallel.
When using the LED Displacement Sensor in combination with
another type of Sensor (such as a Photoelectric Sensor), the sen-
sor beams should be as close to perpendicular as possible.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
CSM_Z4W-V_DS_E_2_1
E217-E1
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Application Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7068/Fax: (81)75-344-7107