English
Language : 

E3X-DAC-S Datasheet, PDF (11/16 Pages) Omron Electronics LLC – Easy and Reliable The Fiber Sensor That Sees in Color
E3X-DAC-S
Precautions for Correct Use
Do not use the product in atmospheres or environments that
exceed product ratings.
Amplifier Unit
● Designing
Operation after Turning Power ON
The Sensor is ready to detect within 200 ms after the power
supply is turned ON. If the Sensor and load are connected to
separate power supplies, be sure to turn ON the Sensor first.
Time may be required for the degree of match to stabilize after
the power supply is turned ON.
Operation When Turning Power OFF
Output pulses may occur when the power is turned OFF. Turn
OFF the power supply to the load and the load line before
turning OFF the power supply to the Sensor.
● Mounting
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
until it clicks into place.
Insert
2. Attach the protector seals (provided as accessories) to the
sides of master and slave connectors that are not
connected.
Adding and Removing Amplifier Units
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and
press the Amplifier Units together until they click into place.
Click
into place
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from
the DIN track one at a time. (Do not attempt to remove
Amplifier Units from the DIN track without separating them
first.)
Note 1. The specifications for ambient temperature will vary according to the
number of Amplifier Unit used together. For details, refer to Ratings
and Specifications on ➜ page 3.
2. Always turn OFF the power supply before joining or separating
Amplifier Units.
Mounting the End Plate (PFP-M)
An End Plate should be used if there is a possibility of the
Amplifier Unit moving, e.g., due to vibration.
Seal
Note: Attach the seals to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit(s) for which the Connector is
to be removed away from the rest of the group.
2. After the Amplifier Unit(s) has been separated, press down
on the lever on the Connector and remove it. (Do not
attempt to remove Connectors without separating them
from other Amplifier Units first.)
Press down
Lever
Remove
End Plate