Low-power buffer and inverter
Table 9. Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); for test circuit see Figure 8.
Symbol Parameter Conditions
25 C
Min Typ[1] Max
CL = 5 pF, 10 pF, 15 pF and 30 pF
CPD
power
fi = 1 MHz; VI = GND to VCC
dissipation
capacitance
VCC = 0.8 V
VCC = 1.1 V to 1.3 V
VCC = 1.4 V to 1.6 V
VCC = 1.65 V to 1.95 V
VCC = 2.3 V to 2.7 V
VCC = 3.0 V to 3.6 V
[3][4]
-
2.5
-
- 2.7 -
- 2.8 -
-
3.0
-
- 3.5 -
- 4.0 -
[1] All typical values are measured at nominal VCC.
[2] tpd is the same as tPLH and tPHL.
[3] All specified values are the average typical values over all stated loads.
[4] CPD is used to determine the dynamic power dissipation (PD in W).
PD = CPD  VCC2  fi  N + (CL  VCC2  fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
(CL  VCC2  fo) = sum of the outputs.
40 C to +125 C Unit
Min Max Max
(85 C) (125 C)
-
-
-
-
-
-
-
-
-
-
-
-
- pF
- pF
- pF
- pF
- pF
- pF
12. Waveforms
VI
1A input
GND
VOH
1Y output
VOL
VM
tPLH
VM
VM
tPHL
VM
VI
2A input
GND
VOH
2Y output
VOL
VM
tPHL
VM
Fig 7.
Measurement points are given in Table 10.
Logic levels: VOL and VOH are typical output voltage levels that occur with the output load.
The data input 1A to output 1Y and input 2A to output 2Y propagation delays
Table 10. Measurement points
Supply voltage
Output
Input
VCC
0.8 V to 3.6 V
VM
VM
VI
0.5  VCC
0.5  VCC
VCC
VM
tPLH
VM
aaa-002992
tr = tf
 3.0 ns
74AUP2G3404
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 1 — 22 August 2012
© NXP B.V. 2012. All rights reserved.
9 of 19