Table 8. Dynamic characteristics …continued
Voltages are referenced to GND (ground = 0 V); CL = 50 pF unless otherwise specified; for test circuit see Figure 8.
Symbol Parameter Conditions
Tamb = −40 °C to +85 °C Tamb = −40 °C to +125 °C Unit
Min Typ[1] Max
Min
Max
ten
enable time nOE to nY; see Figure 7
[2]
VCC = 2.0 V
-
40
115
-
135
ns
VCC = 4.5 V
-
11
23
-
27
ns
VCC = 6.0 V
tdis
disable time nOE to nY; see Figure 7
-
8
20
-
[2]
23
ns
VCC = 2.0 V
-
25
125
-
150
ns
VCC = 4.5 V
VCC = 6.0 V
tt
transition nY; see Figure 6
time
VCC = 2.0 V
-
12
25
-
-
10
21
-
[2]
-
18
75
-
30
ns
26
ns
90
ns
VCC = 4.5 V
-
6
15
-
18
ns
VCC = 6.0 V
-
5
13
-
CPD
power
per buffer; VI = GND to VCC
[3]
dissipation
capacitance
output enabled
-
11
-
-
output disabled
-
1
-
-
15
ns
-
pF
-
pF
74HCT2G126
tpd
propagation nA to nY; see Figure 6
delay
VCC = 4.5 V
[2]
-
15
30
-
36
ns
VCC = 5.0 V; CL = 15 pF
-
12
-
-
ten
enable time nOE to nY; see Figure 7;
VCC = 4.5 V
[2] -
11
31
-
tdis
disable time nOE to nY; see Figure 7;
VCC = 4.5 V
[2] -
11
35
-
tt
transition nY; see Figure 6; VCC = 4.5 V
[2] -
6
15
-
time
-
ns
38
ns
42
ns
18
ns
CPD
power
per buffer;
dissipation VI = GND to VCC − 1.5 V
capacitance output enabled
[3]
-
11
-
-
-
pF
output disabled
-
1
-
-
-
pF
[1] All typical values are measured at Tamb = 25 °C.
[2] tpd is the same as tPLH and tPHL.
ten is the same as tPZL and tPZH.
tdis is the same as tPLZ and tPHZ.
tt is the same as tTHL and tTLH.
[3] CPD is used to determine the dynamic power dissipation (PD in µW).
PD = CPD × VCC2 × fi × N + Σ(CL × VCC2 × fo) where:
fi = input frequency in MHz;
fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in V;
N = number of inputs switching;
Σ(CL × VCC2 × fo) = sum of outputs.