Table 10. Dynamic characteristics 74HCT4067
GND = 0 V; tr = tf = 6 ns; CL = 50 pF unless specified otherwise; for test circuit see Figure 14.
Vis is the input voltage at a Yn or Z terminal, whichever is assigned as an input.
Vos is the output voltage at a Yn or Z terminal, whichever is assigned as an output.
Symbol Parameter
Conditions
25 °C
Typ
Max
tpd
propagation delay Yn to Z; see Figure 12
VCC = 4.5 V
Z to Yn
[1][2]
9
15
toff
turn-off time
VCC = 4.5 V
E to Yn; see Figure 13
VCC = 4.5 V
VCC = 5.0 V; CL = 15 pF
Sn to Yn
6
12
[3]
26
55
26
-
VCC = 4.5 V
VCC = 5.0 V; CL = 15 pF
E to Z
31
55
30
-
VCC = 4.5 V
Sn to Z
30
60
ton
turn-on time
VCC = 4.5 V
E to Yn; see Figure 13
VCC = 4.5 V
VCC = 5.0 V; CL = 15 pF
Sn to Yn
35
60
[4]
32
60
32
-
VCC = 4.5 V
VCC = 5.0 V; CL = 15 pF
E to Z
35
60
33
-
VCC = 4.5 V
Sn to Z
38
65
VCC = 4.5 V
38
65
CPD
power dissipation per switch; VI = GND to (VCC − 1.5 V) [5]
-
29
capacitance
−40 °C to +125 °C Unit
Max Max
(85 °C) (125 °C)
19
22 ns
15
18 ns
69
83 ns
-
- ns
69
83 ns
-
- ns
75
90 ns
75
90 ns
75
90 ns
-
- ns
75
90 ns
-
- ns
81
98 ns
81
98 ns
-
- pF
[1] tpd is the same as tPHL and tPLH.
[2] Due to higher Z terminal capacitance (16 switches versus 1) the delay figures to the Z terminal are higher than those to the Y terminal.
[3] ton is the same as tPHZ and tPLZ.
[4] toff is the same as tPZH and tPZL.
[5] CPD is used to determine the dynamic power dissipation (PD in µW).
PD = CPD × VCC2 × fi + ∑{(CL + Csw) × VCC2 × fo} where:
fi = input frequency in MHz;
fo = output frequency in MHz;
∑{(CL + Csw) × VCC2 × fo} = sum of outputs;
CL = output load capacitance in pF;
Csw = switch capacitance in pF;
VCC = supply voltage in V.
74HC_HCT4067_3