TDA5051ATD-T Datasheet, PDF (12/29 Pages) NXP Semiconductors – Home automation modem | |||
|
◁ |
NXP Semiconductors
TDA5051A
Home automation modem
Table 7. Calculation of parameters depending on the clock frequency â¦continued
Symbol Parameter
Conditions
tW(burst)(min)
tc(AGC)
tsu(demod)
th(demod)
minimum burst time of VO(DC) signal tW(DI)(min) + th
AGC time constant
2514/fosc
demodulation set-up time
3200/fosc (max.)
demodulation hold time
3800/fosc (âmax.)
Unit
s
s
s
s
TX_OUT
VO(DC)
0
DATA_IN
tW(burst)
tW(burst)(min)
tsu
tW(DI)
th
tW(DI)(min)
(1)
(2)
(3)
002aaf044
(1) tW(DI) > tW(DI)(min)
(2) tW(DI)(min) = tsu + 1/fcr
(3) tW(DI)(min) < tsu; wrong operation
Fig 8. Relationship between DATA_IN and TX_OUT (see Table 8)
Table 8. Relationship between DATA_IN and TX_OUT
X = donât care.
PD
DATA_IN TX_OUT
1
X
high-impedance
0
1
0
0
high-impedance (after th)
active with DC offset
100 %
tW(burst)
tsu
th
Fig 9. Pulse shape characteristics
002aaf045
TDA5051A
Product data sheet
All information provided in this document is subject to legal disclaimers.
Rev. 5 â 13 January 2011
© NXP B.V. 2011. All rights reserved.
12 of 29
|
▷ |