English
Language : 

LP3945 Datasheet, PDF (4/15 Pages) National Semiconductor (TI) – Battery Charge Management System
Absolute Maximum Ratings (Notes 1,
2)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
CHG-IN
BATT, VBSENSE, SDA, SCL, EOC,
CHG, EN, BIPB, StopModeEN
Junction Temperature
Storage Temperature
Power Dissipation (Note 3)
−0.3V to +6.5V
−0.3V to +6V
150˚C
−65˚C to +150˚C
1.76W
ESD (Note 4)
Human Body Model
Machine Model
2kV
200V
Operating Ratings (Notes 1, 2)
CHG-IN
EN, BIPB, StopModeEN
Junction Temperature, TJ
Operating Temperature, TA
Thermal Resistance, θJA
Maximum Power Dissipation
(TA = 85˚C, (Note 5) )
3.0V to 6.0V
0V to (VCHG-IN+0.3V)
−40˚C to +125˚C
−40˚C to +85˚C
37˚C/W
1.08W
Electrical Characteristics
Unless otherwise noted, VCHG-IN = 5V, VBATT = 4V, CCHG-IN = 1µF, CBATT = 10µF. Typical values and limits appearing in nor-
mal type apply for TJ = 25˚C. Limits appearing in boldface type apply over the entire junction temperature range for operation,
TJ = −40˚C to +85˚C. (Notes 6, 7, 8)
Symbol
Parameter
Conditions
Typical
Limit
Min
Max
Units
VCC SUPPLY
VCHG-IN
Input Voltage Range
Operating Range
Battery Connected
4.5
6
V
4.5
6
VCHG-IN ≤ 4V
2
20
µA
IBATT
Battery Leakage Current
EOC = Low, adaptor connected,
50
VBATT = 4.1V
VOK−TSHD
Adapter OK Trip Point (CHG-IN) VCHG-IN - VBATT (Rising)
VCHG-IN - VBATT (Falling)
60
50
150
µA
mV
mV
Under Voltage Lock-out Trip
VUVLO−TSHD Point
VCHG-IN (Rising)
VCHG-IN (Falling)
4.15
3.8
4.5
V
3.95
3.6
4.3
V
VOVLO−TSHD
Over Voltage Lock-out Trip Point VCHG-IN (Rising)
VCHG-IN (Falling)
5.9
5.7
V
Thermal Shutdown Temperature
160
˚C
(Note 7)
Thermal Shutdown Hysteresis
20
˚C
BATTERY CHARGER — Li ION MODE (MODE = LOW)
Fast Charge Current Range
500
950
mA
ICHG
Fast Charge Current Accuracy
Programmable Charging Current
Step
−10
+10
%
50
mA
IPRE-CHG
Pre-Charge Current
VBATT = 2V
50
65
mA
IEOC
End Of Charge Current Accuracy For IEOC = 0.1C, 0.15C or 0.2C
+20
−20
%
Battery Regulation Voltage
TJ = 0˚C to +85˚C
4.1
4.059
4.141
ICHARGE = 10 mA, Mode = Low
VBATT
(For 4.1V Cell) (Default State) TJ = −40˚C to +85˚C
4.1
4.038
4.162
ICHARGE = 10 mA, Mode = Low
V
TJ = 0˚C to +85˚C
4.2
4.158
4.242
Battery Regulation Voltage
ICHARGE = 10 mA, Mode = Low
(For 4.2V Cell)
TJ = −40˚C to +85˚C
4.2
4.137
4.263
ICHARGE = 10 mA, Mode = Low
VCHG-Q
Full Charge Qualification
Threshold
VBATT Rising, Transition from
3.0
Pre-Charge to Full Current
V
www.national.com