Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (VCC)
CMOS/TTL Input Voltage
CMOS/TTL Output Voltage
LVDS Receiver Input Voltage
Junction Temperature
−0.3V to +4V
−0.5V to (VCC + 0.3V)
−0.3V to (VCC + 0.3V)
−0.3V to (VCC + 0.3V)
+150˚C
Storage Temperature
−65˚C to +150˚C
Lead Temperature
(Soldering, 4 sec.)
+260˚C
Maximum Package Power Dissipation @ +25˚C
MTD56 (TSSOP) Package:
DS90CR288
1.61 W
Package Derating:
DS90CR288
ESD Rating
(HBM, 1.5kΩ, 100pF)
(EIAJ, 0Ω, 200pF)
Latch Up Tolerance @ +25˚C
12.4 mW/˚C above +25˚C
> 7kV
> 700V
> ±300mA
Recommended Operating
Conditions
Supply Voltage (VCC)
Operating Free Air
Temperature (TA)
Receiver Input Range
Supply Noise Voltage (VCC)
Min Nom Max Units
3.0 3.3 3.6 V
−10 +25 +70 ˚C
0
2.4 V
100 mVPP
Electrical Characteristics
Over recommended operating supply and temperature ranges unless otherwise specified
Symbol
Parameter
CMOS/TTL DC SPECIFICATIONS
VIH
High Level Input Voltage
VIL
Low Level Input Voltage
VOH
High Level Output Voltage
VOL
Low Level Output Voltage
VCL
Input Clamp Voltage
IIN
Input Current
IOS
Output Short Circuit Current
LVDS RECEIVER DC SPECIFICATIONS
VTH
Differential Input High Threshold
VTL
Differential Input Low Threshold
IIN
Input Current
RECEIVER SUPPLY CURRENT
ICCRW
Receiver Supply Current Worst
Case
ICCRZ
Receiver Supply Current Power
Down
Conditions
IOH = −0.4 mA
IOL = 2 mA
ICL = −18 mA
VIN = 0.4V, 2.5V or VCC
VIN = GND
VOUT = 0V
VCM = +1.2V
VIN = +2.4V, VCC = 3.6V
VIN = 0V, VCC = 3.6V
CL = 8 pF,
Worst Case
Pattern
(Figures 1, 2)
f = 33 MHz
f = 40 MHz
f = 66 MHz
f = 75 MHz
PWR DWN = Low
Receiver Outputs Stay Low during
Powerdown Mode
Min Typ Max Units
2.0
GND
VCC
V
0.8
V
2.7
3.3
V
0.06
0.3
V
−0.79 −1.5
V
+1.8 +10
µA
−10
0
µA
−60 −120
mA
−100
+100
mV
mV
±10
µA
±10
µA
49
65
mA
53
70
mA
81
105
mA
110 130
mA
10
55
µA
Note 1: “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. They are not meant to imply that the device
should be operated at these limits. The tables of “Electrical Characteristics” specify conditions for device operation.
Note 2: Typical values are given for VCC = 3.3V and TA = +25˚C.
Note 3: Current into device pins is defined as positive. Current out of device pins is defined as negative. Voltages are referenced to ground unless otherwise
specified (except VTH and VTL).
3