HIGH CURRENT DRIVER ELECTRICAL CHARACTERISTICS
Symbol
ILEAKAGE
IMAX(FLASH)
Parameter
FLASH pin leakage current
Maximum Sink Current
Accuracy @ 300 mA
Current mirror ratio
Condition
RFLASH=1.18 k⦠±1%
20132234
Min Typ Max Units
0.1
2
µA
400 mA
±5 ±10 %
1:300