English
Language : 

9308 Datasheet, PDF (2/6 Pages) National Semiconductor (TI) – Dual 4-Bit Latch
Absolute Maximum Ratings (Note)
If Military Aerospace specified devices are required
please contact the National Semiconductor Sales
Office Distributors for availability and specifications
Supply Voltage
7V
Input Voltage
5 5V
Operating Free Air Temperature Range
MIL
b55 C to a125 C
COM
0 C to a70 C
Storage Temperature Range
b65 C to a150 C
Note The ‘‘Absolute Maximum Ratings’’ are those values
beyond which the safety of the device cannot be guaran-
teed The device should not be operated at these limits The
parametric values defined in the ‘‘Electrical Characteristics’’
table are not guaranteed at the absolute maximum ratings
The ‘‘Recommended Operating Conditions’’ table will define
the conditions for actual device operation
Recommended Operating Conditions
Symbol
VCC
VIH
VIL
IOH
IOL
TA
ts (H)
th (H)
ts (L)
th (L)
tw (L)
tw (L)
trec
Parameter
Supply Voltage
High Level Input
Voltage
Low Level Input
Voltage
High Level Output
Current
Low Level Output
Current
Free Air Operating
Temperature
Setup Time HIGH Dn to En
Hold Time HIGH Dn to En
Setup Time LOW Dn to En
Hold Time LOW Dn to En
En Pulse Width LOW
MR Pulse Width LOW
Recovery Time MR to En
Min
45
2
b55
6
4
10
4
18
18
10
Military
Nom
Max
5
55
08
b0 8
16
125
Commercial
Min
Nom
Max
4 75
5
5 25
2
08
b0 8
16
0
70
10
b2 0
12
8
18
18
8
Units
V
V
V
mA
mA
C
ns
ns
ns
ns
ns
ns
ns
Electrical Characteristics over recommended operating free air temperature (unless otherwise noted)
Symbol
Parameter
Conditions
Min
VI
Input Clamp Voltage
VCC e Min II e b18 mA
VOH
High Level Output
Voltage
VCC e Min IOH e Max
VIL e Max VIH e Min
24
VOL
Low Level Output
VCC e Min IOL e Max
Voltage
VIH e Min VIL e Max
II
Input Current Max
VCC e Max VI e 5 5V
Input Voltage
IIH
High Level Input
VCC e Max VI e 2 4V
Current
IIL
Low Level Input
VCC e Max VI e 0 4V
Current
IOS
Short Circuit
Output Current
VCC e Max
(Note 2)
MIL
COM
b20
b20
ICC
Supply Current
VCC e Max (Note 3)
Note 1 All typicals are at VCC e 5V TA e 25 C
Note 2 Not more than one output should be shorted at a time and the duration should not exceed one second
Note 3 ICC is measured with all outputs open and all inputs grounded
Typ
(Note 1)
Max
b1 5
04
1
40
b1 6
b70
b57
100
Units
V
V
V
mA
mA
mA
mA
mA
2