The second part is the power that is dissipated in the bias and
control circuitry, and can be determined with the formula:
PD(BIAS) = VBIAS × IGND(BIAS)
(2)
where IGND(BIAS) is the portion of the operating ground current
of the device that is related to VBIAS.
The third part is the power that is dissipated in portions of the
output stage circuitry, and can be determined with the formu-
la:
PD(IN) = VIN × IGND(IN)
(3)
where IGND(IN) is the portion of the operating ground current
of the device that is related to VIN.
The total power dissipation is then:
PD = PD(PASS) + PD(BIAS) + PD(IN)
(4)
The maximum allowable junction temperature rise (ΔTJ) de-
pends on the maximum anticipated ambient temperature (TA
(MAX)) for the application, and the maximum allowable oper-
ating junction temperature (TJ(MAX)):
(5)
The maximum allowable value for junction to ambient Ther-
mal Resistance, θJA, can be calculated using the formula:
(6)
Heat-Sinking The TO-220 Package
The TO-220 package has a θJA rating of 60°C/W, and a θJC
rating of 3°C/W. These ratings are for the package only, no
additional heat-sinking, and with no airflow.
The thermal resistance of a TO-220 package can be reduced
by attaching it to a heat-sink or a copper plane on a PC board.
If a copper plane is to be used, the values of θJA will be same
as shown in next section for TO-263 package.
The heat-sink to be used in the application should have a
heat-sink to ambient thermal resistance, θHA:
(7)
where θJA is the required total thermal resistance from the
junction to the ambient air, θCH is the thermal resistance from
the case to the surface of the heat sink, and θJC is the thermal
resistance from the junction to the surface of the case.
For this equation, θJC is about 3°C/W for a TO-220 package.
The value for θCH depends on method of attachment, insula-
tor, etc. θCH varies between 1.5°C/W to 2.5°C/W. Consult the
heat-sink manufacturer datasheet for details and recommen-
dations.
Heat-Sinking The TO-263 Package
The TO-263 package has a θJA rating of 60°C/W, and a θJC
rating of 3°C/W. These ratings are for the package only, no
additional heat-sinking, and with no airflow.
The TO-263 package uses the copper plane on the PCB as
a heat-sink. The tab of this package is soldered to the copper
plane for heat-sinking. The graph below shows a curve for the
θJA of TO-263 package for different copper area sizes, using
a typical PCB with 1 ounce copper and no solder mask over
the copper area for heat-sinking.
20202625
FIGURE 1. θJA vs Copper (1 Ounce) Area for the TO-263
package
As shown in Figure 1, increasing the copper area beyond 1
square inch produces very little improvement. The minimum
value for θJA for the TO-263 package mounted to a PCB is
32°C/W.
Figure 2 shows the maximum allowable power dissipation for
TO-263 packages for different ambient temperatures, assum-
ing θJA is 35°C/W and the maximum junction temperature is
125°C.
20202626
FIGURE 2. Maximum Power Dissipation vs Ambient
Temperature for TO-263 package
11