SM8760CA Datasheet, PDF (4/8 Pages) Nippon Precision Circuits Inc – Spread Spectrum Clock Generator | |||
|
◁ |
SM8760CA
AC Characteristics
VDD = 3.3 ± 0.3V, VSS = 0V, Ta = â20 to +80°C unless otherwise noted.
Parameter
Symbol
Pins
Condition
Rating
Unit
min
typ
max
Clock frequency
Crystal connection
f in
XT
External clock input*1
â
12.75
â
MHz
â
12.75
â
Output clock rise time*2
tr
CLKOUT, CL = 15pF, VOL = 0.2VDD to VOH =
REFOUT 0.8VDD transition time
â
2.0
â
ns
Output clock fall time*2
tf
CLKOUT, CL = 15pF, VOH = 0.8VDD to VOL =
REFOUT 0.2VDD transition time
â
2.0
â
ns
1-sigma jitter, Ta = 25°C, CL = 15pF,
VO = 0.5VDD
â
25
â
REFOUT
Output clock jitter*2
tjitter
Peak-to-peak jitter, Ta = 25°C,
CL = 15pF, VO = 0.5VDD
â
180
â
ps
CLKOUT
Cycle-to-cycle jitter, Ta = 25°C,
CL = 15pF, VO = 0.5VDD
â
350
â
Output clock duty
cycle *2
Dt
CLKOUT,
REFOUT
Ta = 25°C, CL = 15pF, VO = 0.5VDD
45
50
55
%
Power-up time*2,*3
tp
CLKOUT,
REFOUT
â
1
5
ms
*1. When using an external clock input, it is recommended that the clock on XT have 50% duty and VDD level signal amplitude. Note that the input signal
voltage must not exceed the absolute maximum rating, otherwise it may cause the device to breakdown.
*2. Measured using the circuit in Figure 1 on the NPC standard evaluation board.
*3. The power-up time is the time from when the supply reaches 3.0V after the supply is turned ON until each output clock reaches its designated fre-
quency to within ± 0.1%.
X'tal
+
+
DUT
DUT: Device Under Testing
Active Probe
(HP1152A)
Passive Probe
(HP10435A)
Oscilloscope
(Infinium
HP54845A)
Frequency &
Time Interval
Analyzer
(HP5371A)
Figure 1. Measurement circuit
Jitter
Measurement
System
(ASA, M1)
SEIKO NPC CORPORATION â4
|
▷ |