PXI-4204 Datasheet, PDF (1/4 Pages) National Instruments Corporation – DAQ for High-Voltage Measurements 16-Bit, 200 kS/s, 8 Analog Inputs
DAQ for High-Voltage Measurements
16-Bit, 200 kS/s, 8 Analog Inputs
NI PXI-4204
• 8 analog inputs at 200 kS/s,
16-bit resolution
• ±100 V input range
• Programmable gain (0.5, 1, 10, 100)
per channel
• Programmable 2-pole Butterworth
filter (6 Hz or 10 kHz) per channel
• Differential simultaneous
sampling inputs
• Combicon screw terminal
direct connectivity
• NI-DAQ driver simplifies
configuration and measurements
Operating Systems
• Windows 2000/NT/XP
Recommended Software
• LabVIEW
• LabWindows/CVI
• Measurement Studio for
Visual Studio.NET
Other Compatible Software
• Visual Basic, C/C++, and C#
Driver Software (Included)
• NI-DAQ 7
New
Device
NI PXI-4204
Bus
Analog Inputs
Resolution
PXI
8 DI
16 bits
Table 1. NI PXI-4204 Channel, Speed, and Resolution Specifications
Overview and Applications
The National Instruments PXI-4204 module delivers accurate data
acquisition for input ranges up to 100 V. With this module you can
handle a broad variety of applications including:
• 42 V automotive applications
• High-voltage, multichannel data logging applications
• Fuel cell and battery test applications
Features
The NI PXI-4204 is a full-featured data acquisition module with a
±100 V input range, 16-bit accuracy, and software-selectable filter
and gain settings per channel. Programmable filter and gain settings
ensure that the PXI-4204 achieves maximum accuracy over the
entire ±100 V input range. In addition, the PXI-4204 is designed to
work with LabVIEW 7 Express and NI-DAQmx. The DAQ Assistant
in LabVIEW 7 can configure the PXI-4204 and acquire data through
a menu-based window, eliminating the need to manually program
the device.
Sampling Rate
200 kS/s
Input Range
±0.5 to ±100 V
Triggers
Digital (2)
Filter Settings
2-pole Butterworth
(6 Hz or 10 kHz)
Driver Software
NI-DAQ 7 is the robust driver software included with all
National Instruments data acquisition and signal conditioning
products. This easy-to-use software tightly integrates the full
functionality of your DAQ hardware to LabVIEW, LabWindows/CVI,
and Measurement Studio for Visual Studio.NET. High-performance
features include multidevice synchronization, networked
measurements, and DMA data management. Bundled with
NI-DAQ 7, the Measurement & Automation Explorer (MAX) utility
simplifies the configuration of your measurement hardware with
device test panels, interactive measurements, and scaled I/O
channels. NI-DAQ also provides numerous example programs for
LabVIEW and other application development environments to get
you started with your application quickly.
For high-channel-count, high-voltage applications, explore NI signal
conditioning hardware. Visit ni.com/sigcon
Ordering Information
NI PXI-4204 ......................................................778745-4204
Includes NI-DAQ driver software.
For more information on extended warranty and value-